automiX2 cartriDges 1:1 – lite, Xlite, mono, monoPrint suPra, antilock
The cartridges are emptied with the Automix2 system pistol (Fig. 5). After inserting the cartridge into the mixing gun, remove
the cartridge closure by turning it. Squeeze out a small amount of material until silicone is being uniformly emitted from both
outlet openings (Fig. 6). Attach the mixing cannula in accordance with the guides on the cannula and cartridge, and lock it
by turning it in the opposite direction (Fig. 7). Emit material with even pressure. Spread a small amount of material before
use and visually check that the base and catalyst pastes are homogeneously mixed (Fig. 8). Only then can the metering be
carried out individually. After use, leave the mixing cannula on the cartridge until the next application.
Disinfection
After taking the impression out of the mouth, rinse it under running lukewarm water. Subsequent disinfection can be carried
out with suitable commercially available disinfecting solutions according to the manufacturer's instructions.
ProDucing the laboratory moDel
With dental plaster type III – V, this can be done already about 30 minutes after removal from the mouth.
tray cleaning
Remove cured material mechanically. Placing in acetone or isopropanol dissolves trayloc® A. Use only in well-ventilated areas.
Then clean and disinfect the tray as usual.

safety information

Only
for the specified intended use by trained personnel.
monoprint supra: Reliable fixation of transfer posts and retention parts is significantly improved by application of trayloc® A.
Detaseal® antilock: Does not react with polyether impression materials, condensation-curing silicones and alginates;
pay attention to sufficient material thickness.
In order to prevent locking in marked undercuts, these can be filled up with Detaseal® antilock in advance to facilitate
removal of single-step impressions from the mouth. Do not apply Detaseal® antilock in preparation areas. Use only as
block-out material.
Detaseal® antilock does not react with polyether impression materials, condensation-curing silicones and alginates.
Solutions used prior to impression taking (e.g. retraction solutions) may affect the curing reaction and must therefore
be removed completely.