The pump does not start at the set times
Ensure correct settings of the operating times and days.
The pumps starts, but operation is interrupted after a few seconds
The presence of air in the intake hose may prevent correct operation of the system; try to increase the
"Stop Delay" parameter to enable longer operation also when no flow is detected.
When the power is disconnected the device does not maintain the current time in the memory
The internal battery may be discharged; arrange for the device to be checked by the manufacturer.
The device does not turn on
The electronic board may be damaged; arrange for the device to be checked by the manufacturer.

MAINTENANCE:

Crono Spy has been designed to reduce maintenance requirements to a minimum. Always observe the
following instructions to ensure prolonged efficiency of the device:
- never allow the device to reach temperatures below 3° C; if this is not possible, ensure that all the water
in the circuit is drained to prevent damage to the plastic housing of the device if ice forms;
- if the pump is equipped with filters on intake, check their condition periodically;
- always ensure that the cover is closed properly to avoid the ingress of water from outside;
- disconnect the power and drain water from the system when the system is not to be used for a prolonged
period;
- before using the device with liquids other than water, contact the manufacturer for further information;
- never perform work with the device open;
- the internal battery must only be replaced by the manufacturer
- before removing the device cover, wait for 3 minutes to enable discharge of the capacitors.
CAUTION: the device does not contain components that may be repaired or replaced by the
final user. Therefore do not remove the protection cover of the electronic board to avoid rendering
the guarantee null and void.
Date of installation
Client
Pump brand-model
CronoSpy Serial N°
FACTORY SETTINGS ON INSTALLATION
Stop delay
Imax
Notes
..../..../.......
Installer
Seconds
A
28

Publicité

Table des Matières
loading

Table des Matières