Télécharger Imprimer la page

Troubleshooting - Gardena SmallCut 300 Accu Mode D'emploi

Masquer les pouces Voir aussi pour SmallCut 300 Accu:

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 17

8. Troubleshooting

Risk of Injury !
Pulling the cutting filament
manually out of the
filament cassette:
21
Releasing a cutting filament that
has gone into the cassette or
which has fused:
19
21
Fault
The Turbotrimmer
no longer cuts
Charging indicator lamp does
not light up
Charging indicator lamp
flashes for more than
1 hour
The battery can no longer
be charged
In the event of other faults please contact GARDENA Service.
Repairs should only be carried out by GARDENA service centres or dealers authorised by
GARDENA.
Risk of injury from the cutting filament!
Always remove the battery pack of the Turbotrimmer before
troubleshooting.
Risk of injury from the filament limiter !
Keep fingers away from the filament limiter
After extending the cutting filament always return the trimmer
to its normal operating position before switching on.
A cutting filament that is too short or no longer extends
automatically when the trimmer is turned on can be pulled out
manually.
5
1. Remove the battery pack.
2. Hold the automatic slide feed (21) down with your hand and at
the same time pull on the cutting filament (5).
If the cutting filament has disappeared into the filament cassette or if the
automatic filament extension still doesn't work after pulling the cutting
filament (5) it may be fused together in the filament cassette (19).
1. Remove the battery pack.
2. Remove the filament cassette (19) as described in
6. Maintenance " Replacing the filament cassette ".
3. Unwind the cutting filament (5), clean the filament cassette (19)
and the cutting filament (5) and wind the cutting filament (5)
5
onto the cassette (19) once more.
4. Clean the automatic mechanism lever (21). The automatic lever
must move freely.
5. Insert the filament cassette again as described under
6. Maintenance " Replacing the filament cassette ".
Possible cause
Filament cassette empty.
Cutting filament too short or the
automatic filament extension
Cutting filament inside the
cassette or fused.
Battery not plugged
in properly.
A fault has occurred.
Battery is defective.
Remedy
Replace the filament cassette
(see 6. Maintenance
"Replacing the filament
cassette" ).
Pull the filament out of the
cassette manually.
Release filament that has
disappeared into the
cassette or fused together.
Plug in battery charger
and charging cable
properly.
Unplug and reinsert
charging cable. The fault
will be reset.
Replace the battery
(Art. 8834).
15

Publicité

loading

Ce manuel est également adapté pour:

8844