Connect Blower Electrical Parts
1. Locate the capacitor (in Blower Motor Kit).
NOTE: The capacitor is supplied with a small harness that
terminates in a two-pin connector as shown.
2. Locate the capacitor storage tray in front of the blower bellow
connection point in the lower right side of the range.
3. Place capacitor in tray.
4. Secure the capacitor with the capacitor retention bracket, then
install the bracket screw.
28
5. Secure the blower motor strain relief, near the quick
connection end, to the blower electrical terminal cover with the
two provided screws.
6. Locate the two-pin connector on the blower motor wire
harness and connect it to the two-pin capacitor connector.
7. Locate the 4-pin connector on the blower motor wire and plug
it into the terminal connection point directly behind the
capacitor storage tray.
NOTE: The terminal release (clip point) will be facing toward
the front of the range.
8. Install blower electrical terminal cover.
NOTE: When replacing cover, insert the terminal cover tabs in
the corresponding slots in the range, and push the terminal
cover rearward to engage.