2.1 Technical Specification

Flow Data
Model
BAM10
BAM20
BAM30
BAM40
BAM50
BAM70
Stated flows are for operation at 7 bar g (100 psi g / 0.7 MPa g) with reference to 20ºC, 1 bar a, 0% relative water vapour pressure.
Performance
Dryer Model
All Models
ISO 8573-1 classifications apply when the dryer is installed with the filtration supplied
Contaminants
Oil / Lubricant
Water
Carbon Monoxide (CO)
Carbon Dioxide (CO
)
2
Oxygen (O
)
2
Nitrogen Oxides (NO + NO
)
2
Sulphur Dioxide (SO
)
2
o
Reference conditions: 20
C, 1 bar(a), dry. Compressed air conditions: 7 bar overpressure, 35
Operating Data
Min Operating Pressure
Model
All Models
Electrical Data
Supply Voltage
Connection Type
Power
1
Fuse
1 Fuses are Anti surge (T) 250VAC, 5x20mm, HBC, Breaking capacity 1500A @250VAC, IEC 60127-2, UL/CSA Ceramic body.
Pipe Size
L/s
m
G 2Ý
113
G 2Ý
170
G 2Ý
213
G 2Ý
283
G 21/2Ý
354
G 21/2Ý
496
Pressure Dewpoint
(Standard)
o
o
C
F
-40
-40
Units
3
mg/m
Ref.
ppm
ppm
ppm
Vol.-%
ppm
ppm
Max Operating
bar g
psi g
bar g
4
58
13
BAM10
BAM20
Inlet
3
3
cfm
/min
m
/hr
6.8
408
240
10.2
612
360
12.8
765
450
17.0
1020
600
21
1275
750
30
1785
1050
ISO 8573-1:2010
Water Classification
(Standard)
Class 2
Inlet Challenge
(All Models)
11.3
7,913
39
744
20.9
13
7
o
C
Min Operating
Pressure
Temperature
o
psi g
C
188.5
5
BAM30
90 - 264V 1PH 50/60Hz
Hard wired
21 W (Max)
T3.15A
Outlet
3
L/s
m
/min
90.4
5.4
136
8.2
170.4
10.2
226.4
13.6
283.2
16.8
396.8
24
Outlet Levels
(All Models)
0.011
24
<0.01
109
20.9
1.8
<0.01
Max Operating
Temperature
o
o
o
F
C
F
41
35
95
BAM40
BAM50
3
cfm
m
/hr
326.4
192
489.6
288
612
360
816
480
1020
600
1428
840
European
Pharmacopoeia
0.1
67
5
500
20.4 - 21.4
2
1
BAM70
3