Problem and alarm code
Malfunction of the wash
pump or the drain pump.
The lights related to
MY TIME selection bar
flash 5 times intermittent‐
ly.
An acoustic signal
sounds intermittently.
The temperature of the wa‐
ter inside the appliance is
too high or malfunction of
the temperature sensor oc‐
curred.
The lights related to
MY TIME selection bar
flash 6 times intermittent‐
ly.
An acoustic signal
sounds intermittently.
Technical malfunction of the
appliance.
The lights related to
MY TIME selection bar
flash 12 times intermit‐
tently.
An acoustic signal
sounds intermittently.
The level of water inside the
appliance is too high.
The lights related to
MY TIME selection bar
flash 15 times intermit‐
tently.
An acoustic signal
sounds intermittently.
The appliance stops and
starts more times during op‐
eration.
The programme lasts too
long.
Possible cause and solution
Switch the appliance off and on.
Make sure that the temperature of the inlet water does
not exceed 60°C.
Switch the appliance off and on.
Switch the appliance off and on.
Switch the appliance off and on.
Make sure that the filters are clean.
Make sure that the outlet hose is installed at the right
height above the floor. Refer to the installation instruc‐
tions.
It is normal. It provides optimal cleaning results and en‐
ergy savings.
If the delay start option is set, cancel the delay setting or
wait for the end of the countdown.
Activating ExtraPower increases the programme dura‐
tion.