Flush mounting: Flush mounting into a countertop is
possible.
Flush installation: The appliance can be installed in the
following temperature- and water-resistant countertops:
Stone countertops
Plastic countertops (such as Corian®)
Solid wood countertops: Only in consultation with the
manufacturer of the countertop (seal cut-out edges)
Installation in other countertops only in consultation
with the manufacturer of the countertop.
Installation in countertops made of particleboard is not
possible.
Note: Any cut-out work on the countertop must be
performed in a workshop according to the installation
diagram. The cut-out must be made cleanly and precisely
since the cut-out edge is visible on the surface. Clean
and degrease the cut-out edges with a suitable cleaning
agent (bear in mind silicone manufacturer's processing
instructions).
Combining several Vario devices: The connecting strip
VA 420 000/010 is required for the combination of
several Vario appliances. This is available separately as a
special accessory. Consider additional space
requirement for the connecting strip between the
appliances when making the cut-out (see installation
instructions VA 420 000/010).
Prepare Installation Space
Appliances can also be installed in individual cut-outs,
bearing in mind a minimum distance between the devices
of 2" (51 mm).
In combination with appliance cover: The appliance cover
VA 440 010 can be ordered separately as an optional
accessory. Take into account the additional space
required for the appliance cover when making the cutout.
Flush mount installation: