Filter Cleaning Pag - Nilfisk SR1005B Mode D'emploi Et D'entretien

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

56041505(2)2001-01
FILTER CLEANING
The panel filter should be cleaned regularly,
depending on the machine working conditions
(amount of dust). To clean the panel filter it must
be removed from the machine. To remove it:
lift the seat cover and rotate the two levers 180˚ as
shown in Figure 17.
Next, widen the lever support brackets (Fig. 17).
Disconnect the filter-shaker wire-harness as shown
in (Fig. 18)
Move the filter cover forward.
Pull out the panel filter (Fig. 19)
Blow compressed air through the filter, max. 6 bar
(87 psi). only from the grate protected side. (Fig. 20)
Before reassembling the filter make sure that the
filter has not been damaged. If it is damaged or if it
is not possible to clean, it should be replaced.
Ask your Advance dealer for the required spare
parts.
Note: washable polyester as well as antistatic filters
are available as options. (see OPTIONS section)
6

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

908 3509 010

Table des Matières