Installation Instructions

Water and Drain Requirements

POTABLE WATER REQUIREMENTS

Follow these guidelines to install water inlet lines:
Do not connect the ice machine to a hot water
supply. Be sure all hot water restrictors installed for
other equipment are working. (Check valves on sink
faucets, dishwashers, etc.)
If water pressure exceeds the maximum of 80 psig
(552 kPA) recommended pressure, obtain a water
pressure regulator from your Manitowoc distributor.
Install a water shut-off valve and union for both the
ice making and condenser water lines.
Insulate water inlet lines to prevent condensation.
Plumbing must conform to local codes.
SEPERATE BIN AND ICE
MACHINE DRAINS ARE
REQUIRED
ROUTE DRAIN TUBING TO
OPEN SITE DRAIN

DRAIN CONNECTIONS

Follow these guidelines when installing drain lines to prevent
drain water from flowing back into the ice machine and storage
bin:
Drain lines must have a 1.5 inch drop per 5 feet of run (2.5
cm per meter), and must not create traps.
The floor drain must be large enough to accommodate
drainage from all drains.
Run separate bin and water-cooled condenser drain lines.
Insulate them to prevent condensation.
7
VENT TUBE
18" (46 CM)
LONG
Typical Water Supply Drain Installation
WATER SUPPLY AND DRAIN LINE SIZING/
CONNECTIONS
Water Temp
Location
Min/Max
40°/90°F
Potable
Water Inlet
(4°/32°C)
Potable
---
Water Drain
40°/90°F
Condenser
Water Inlet
(4°/32°C)
Condenser
---
Water Drain
Bin Drain
---
Large Capacity Bin Drain
WATER SHUT-OFF VALVE
REQUIRED - ICE MAKING
WATER INLET TUBING 3/8"
MIN. I.D. (.95 CM)
ICE MAKING
WATER INLET
TUBING 3/8" MIN.
I.D. (.95 CM)
VENT TUBE
18" (46 CM)
LONG
Vent the bin and ice machine drain to the atmosphere. The
ice machine drain requires an 18" (46 cm) vent. Do not
vent the condenser drain on water-cooled models.
Drains must have a union or other suitable means to allow
in place disconnection from the ice machine when
servicing is required.
Section 2
Water
Fitting/Min
Pressure
Tubing
Min/Max
Size
14/80 psi
3/8" FPT
(100/552 kPA)
---
1/2" MPT
3/8" FPT
20/150 psi
RF2300 only
(138/1034 kPA)
= 1/2" FPT
---
1/2" MPT
---
3/4" FPT
---
1" FPT
ROUTE
DRAIN
TUBING TO
OPEN SITE
DRAIN
Part Number 000007644 3/11