If a problem arises during operation of your ice machine, follow the checklist below before calling service. Routine
adjustments and maintenance procedures are not covered by the warranty.
Problem
Ice machine does not operate.
Gearmotor runs and no ice is produced
25
Section 5

Customer Support

Possible Cause
No electrical power to the ice machine
and/or condensing unit.
High pressure cutout tripping.
Power switch set improperly.
Bin Thermostat Open or Ice touching
thermostat probe.
No water in reservoir
Evaporator safety thermostat open
Ice chute switch open
Low air temperature around ice machine
Time delay has not expired
High pressure cutout tripping
Low pressure control open
To Correct
Replace the fuse/reset the breaker/turn
on the main switch.
Clean condenser coil. (See Section 4)
Move the switch to the ON position.
Adjust thermostat or remove ice
No water to ice machine, plugged filter,
float valve defective
Adjust thermostat
Check for ice or binding and close switch
Air temperature must be at least 35°F
(2°C)
Wait 10 minutes for time delay to expire
Clean condenser coil and reset
Thaw evaporator and retest - Call for
service
Part Number 000007644 3/11