Maintenance, Cleaning And Decontamination; Autoclavable Parts - Nilfisk VHS110N1 CR Manuel D'instructions

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

VHS110N1 CR
Maintenance, cleaning and
decontamination
To guarantee the safety level of the vacuum cleaner,
only original spare parts supplied by the manufacturer
should be used.
The precautions described below must be taken
during all maintenance operations, including cleaning
and replacing the primary and absolute filters.
The maintenance, cleaning and decontamination
operations must only be performed with the
vacuum cleaner turned off with switch and the plug
disconnected from the power socket.
It is absolutely forbidden to perform maintenance with
the plug connected to the socket.
Danger of electric shock!
If the user is performing the maintenance operations,
the vacuum cleaner must be disassembled, cleaned
and overhauled as far as reasonably possible without
hazards for the maintenance personnel or other people.
The suitable precautions include decontamination before
disassembling the vacuum cleaner, adequate filtered
ventilation of the exhaust air from the room in which it
is disassembled, cleaning the maintenance area and
suitable personal protection.
A check must be carried out by qualified personnel at
least once a year. For example: check the air filters to
find out whether the air-tightness of the vacuum cleaner
has been impaired in any way and make sure the electric
control panel operates correctly.
The procedures for servicing and emptying the
vacuum cleaner, including removing the dust
container, must only be performed by authorized
US
personnel wearing protective clothing.
C424
WARNING!
WARNING!
WARNING!
WARNING!

Autoclavable parts

This vacuum cleaner is composed of autoclavable and NON
autoclavable parts.
- All stainless steel parts and silicone rubber gaskets can
be cleaned / decontaminated by means of an autoclave at
121C/250F this will secure an absolute decontamination of
the parts.
The autoclavable parts are:
• Trolley (without wheels)
• Dust container (with wheels and release handle)
• Filter chamber
• Screws, nuts etc.
• Silicone rubber gaskets
• Inlet (without seal to be replaced)
• All accessories: Hoses, nozzles and white silicone hose.
All NON autoclavalbe parts shall be cleaned by means an
appropriate detergents / sanitizers, to ensure an absolute
clean surface and to prevent any bacterial growth or the like.
The NON autoclavable parts are:
• Motor unit
• Machine wheels fixed to the trolley
• Filter chamber with PullClean system
• Knobs for the filter chamber release
• Plastic parts
• Filter
• Bag
In order to secure a complete cleaning of the NON
autoclavable parts the appliance needs to be dismantled
before the cleaning operation.