FOR YOUR SAFETY

DO NOT STORE OR USE GASOLINE OR OTHER
FLAMMABLE VAPORS AND LIQUIDS IN THE
VICINITY OF THIS OR ANY OTHER APPLIANCE.
DO NOT ATTEMPT TO START THE BURNER
WHEN EXCESS OIL HAS ACCUMULATED, WHEN
THE FURNACE IS FULL OF VAPOR OR WHEN THE
COMBUSTION CHAMBER IS VERY HOT.
WARNING
For use with grade 2 Fuel Oil maximum. Do
Not use Gasoline, Crankcase Oil or any Oil
containing Gasoline!
CAUTION
Never burn garbage or paper in the heating
system and never leave rags or paper
around the unit.
CAUTION
These instructions are intended to be used
by qualified personnel who have been
trained in installing this type of furnace.
Installation of this furnace by an unqualified
person may lead to equipment damage
and/or hazardous condition, which may lead
to bodily harm.
Models cross-reference table
Models
AMP1-IE2
AMP2-IE2
1)
GENERAL
This furnace is a true multipositions unit, in that it may
be operated in all four positions when it use with
chimney, i.e., upflow, counterflow (downflow), and
horizontal (both left-to-right and right-to-left airflow).
Very few modifications are required to change the
furnace from one position to another at the job site.
The furnace is shipped in the upflow configuration-
INSTALLATION
BMF-090
LBM090
BMF-125
LBM120
PART 1
instructions on changing to other configurations are on
this document.
It is shipped as a packaged unit, complete with burner
and controls.
connection to the control box, a thermostat hook-up as
shown on the wiring diagram, oil line connection (s),
adequate ductwork, and connection to a properly sized
vent.
IMPORTANT: For sealed combustion system (SCS)
refer to the SCS-4 instruction manual. The appliance
must be installed in upflow position when used with a
SCS
IMPORTANT:
requirements governing the installation of oil burning
equipment, wiring and flue connections must be
followed. Some of the codes that may be applicable
are:
CSA B139
ANSI/NFPA 31
ANSI/NFPA 90B WARM AIR HEATING AND AIR
ANSI/NFPA 211 CHIMNEYS, FIREPLACES, VENTS
ANSI/NFPA 70
CSA C22.2 No.3 CANADIAN ELECTRICAL CODE
Only the latest issues of the above codes should be
used, and are available from either:
The National Fire Protection Agency
Batterymarch Park
Qunicy, MA 02269
or
The Canadian Standards Association
178 Rexdale Blvd.
Rexdale, Ontario M9W 1R3
The air handling capacity of this furnace is designed
for cooling airflow. Refer to table # 4 for the expected
airflow at various externals duct static pressures.
It requires a line voltage (115VAC)
All
local
and
national
INSTALLATION CODE FOR OIL
BURNING EQUIPMENT
INSTALLATION OF OIL BURNING
EQUIPMENT
CONDITIONING SYSTEMS
AND SOLID FUEL BURNING
APPLIANCES
NATIONAL ELECTRICAL CODE
code
3