Technical Data
Electrical contact life
to 5 A, AC 230 V cos ϕ = 1:
Permissible switching
capacity:
Short circuit strength
max. fuse rating:
Line circuit breaker:
Mechanical life:
General Data
Nominal operating mode:
Temperature range
operation:
storage :
altitude:
Clearance and creepage
distances
rated impuls voltage /
pollution degree:
EMC:
Interference suppression:
Degree of protection
Housing:
Terminals:
Housing:
Vibration resistance:
Climate resistance:
Terminal designation:
Wire fixing:
Fixing torque:
Mounting:
Weight
BG 5933:
BH 5933:
Dimensions
Width x height x depth
BG 5933:
BH 5933:

UL-Data

The safety functions were not evaluated by UL. Listing is accom-
plished according to requirements of Standard UL 508, "general
use applications"
Nominal voltage U
:
N
BG 5933:
BH 5933:
Ambient temperature:
Switching capacity:
Ambient temperature 45°C:
Ambient temperature 55°C:
Wire connection:
Technical data that is not stated in the UL-Data, can be found
in the technical data section.
nfo
2 x 10
switching cycles
5
max. 1 800 switching cycles / h
6 A gL
IEC/EN 60 947-5-1
C 8 A
10 x 10
switching cycles
6
continuous operation
- 25 ... + 55°C
- 25 ... + 85 °C
< 2.000 m
4 kV / 2 (basis insulation) IEC 60 664-1
IEC/EN 62 061
Limit value class B
EN 55 011
IP 40
IEC/EN 60 529
IP 20
IEC/EN 60 529
Thermoplast with V0 behaviour
according to UL subject 94
Amplitude 0.35 mm,
frequency 10 ... 55 Hz IEC/EN 60 068-2-6
25 / 055 / 04
IEC/EN 60 068-1
EN 50 005
Terminal screws M3.5
Box terminals with self-lifting wire
protection
0.8 Nm
DIN rail
IEC/EN 60 715
200 g
400 g
22.5 x 84 x 121 mm
45.0 x 84 x 121 mm
AC 24V , DC 24 V
AC 24, 42, 48, 110, 120, 230 V
DC 24V
-15 ... +55°C
Pilot duty B300
5A 250Vac G.P.
5A 24Vdc
Pilot duty B300
4A 250Vac G.P.
4A 24Vdc
60°C / 75°C copper conductors only
AWG 20 - 12 Sol Torque 0.8 Nm
AWG 20 - 14 Str Torque 0.8 Nm

Standard Types

BG 5933.22/61 DC 24 V
Artikelnummer:
• Ausgang:
• Nennspannung U
:
N
• Baubreite:
BH 5933.48/61 AC 230 V
Artikelnummer:
• Ausgang:
• Nennspannung U
:
N
• Baubreite:

Ordering example

B_ 5933
.22 /61 DC 24 V

Troubleshooting

Failure
LED "Power" does not light up
LED "K1" lights up,
but "K2" remains off
or
LED "K2" lights up,
but "K1" remains off
Device cannot be activated

Maintenance and repairs

- The device contains no parts that require maintenance.
- In case of failure, do not open the device but send it to manufacturer
for repair.
17
0063397
2 Schließer, 1 Öffner
DC 24 V
22,5 mm
0061926
3 Schließer, 1 Öffner
AC 230 V
45 mm
Nominal voltage
with UL approval
Contacts
G: 22.5 mm width
H: 45 mm width
Potential cause
Power supply not connected
- Safety relay K1 e.g. K2 is welded
(replace device)
- The 2-Hand-buttons have not been
operated simultaneously within ≤ 0,5s
- Safety relay is welded
(replace device)
- Feddback circuit Y1-Y2
not closed
- The 2-Hand-buttons have not been
operated simultaneously within ≤ 0,5s
BG 5933, BH 5933 / 11.06.18 en / 993