Remove Parts For Cleaning - Manitowoc NEO UD0140A Manuel D'instructions

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Section 4

REMOVE PARTS FOR CLEANING

!
Disconnect electric power to the ice machine at the
electric switch box before proceeding.
A. Remove the Ice Thickness and Harvest Float
Switch
Pull forward on the bottom of the bracket until clear of
the tab, then slide bracket upward to remove the
bracket and float switch as an assembly.
NOTE: At this point, the float switch can easily be
cleaned. If complete removal is desired follow the wires
to the bulkhead grommet (exit point) in the back wall.
Pull the wire connector through the bulkhead grommet,
then disconnect the wire leads from the connector.
Important
Reversing the mounting location of the ice thickness and
the harvest floats will result in a safety limit 3 failure.
The ice thickness float must be mounted to the front
of the water trough and the electrical connection
must be in the top bulkhead grommet.
The harvest float must be mounted to the side of the
water trough and the electrical connection must be in
the bottom bulkhead grommet.
The wire connectors for each float are different and
will not allow incorrect electrical bulkhead
connection.
Part Number 040002909 Rev01 4/15
Warning
WIRE CONNECTORS ARE LOCATED BEHIND BULKHEAD - PULL
THROUGH GROMMET TO DISCONNECT
ICE THICKNESS FLOAT
SWITCH & BRACKET
HARVEST FLOAT SWITCH & BRACKET
DISCONNECT WIRES
FOR COMPLETE
REMOVAL
Harvest or Ice Thickness Float Switch Removal