Water Supply And Drain Line Sizing/Connections - Manitowoc NEO UD0140A Manuel D'instructions

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Section 2

Water Supply and Drain Line Sizing/Connections

Location
Temperature
Ice Making
40F (4C) Min.
Water Inlet
90F (32C) Max.
Condenser Water
Inlet
40F (4C) Min.
90F (32C) Max.
Condenser Water
Drain
Bin Drain
ICE THICKNESS ADJUSTMENT
The ice thickness can be adjusted to three levels.
1. Pull forward on the bottom of the bracket until clear
of the tab.
2. Slide the bracket over the desired tab and release.
The center position is the normal factory setting.
To increase bridge thickness, raise the water level.
To decrease bridge thickness, lower the water level.
Thicker 
Bridge
Total ice weight from one cycle
Model
Minimum - Maximum
U140
1.13 - 1.36 lbs
U190
2.26 - 2.93 lbs
U240
2.26 - 2.93 lbs
U310
2.26 - 2.93 lbs
Part Number 040002909 Rev01 4/15
Water
20 psi (137.9 kPA) Min.
80 psi (551.5 kPA) Max.
20 psi (137.9 kPA) Min.
150 psi (1034.2 kPA) Max.
---
---
Factory 
Thinner 
Default
Setting
Bridge
Minimum - Maximum
513 - 617 grams
1025 - 1329 grams
1025 - 1329 grams
1025 - 1329 grams
Water
Pressure
3/8" Female Pipe
3/8" Female Pipe
1/2" Female Pipe
---
1/2" Female Pipe
---
1/2" Female Pipe
WATER/DRAIN CONNECTIONS
A. Potable Water Inlet
B. Drain
C. Condenser Water Inlet - (Water-cooled Only)
D. Condenser Water Outlet - (Water-cooled Only)
Installation Instructions
Ice Machine
Tubing Size Up to Ice
Fitting
Machine Fitting
3/8" (9.5 mm) minimum
Thread
inside diameter
3/8" (9.5 mm) minimum
Thread
inside diameter
U310 Only
1/2" (12.7 mm)
Thread
minimum inside diameter
1/2" (12.7 mm) minimum
Thread
inside diameter
1/2" (12.7 mm) minimum
Thread
inside diameter
U310 Only
C
D
A
B
11

Publicité

Chapitres

Table des Matières
loading

Ce manuel est également adapté pour:

Neo ud0140wNeo ud0140aeNeo uy0140aNeo uy0140wNeo uy0140aeNeo ur0140a ... Afficher tout

Table des Matières