menu - settings
GB
4
2
0
4
2
1
4
2
2
4
2
3
4
2
4
4
2
5
4
2
6
4
2
7
4
2
8
4
3
4
3
0
4
3
1
4
3
2
4
3
3
4
3
4
4
3
5
4
4
4
4
0
96
DESCRIPTION
Zone 1 temperature range
Thermoregulation
Slope
Offset
Room Infl uence Proportional
Max T
Min T
Heating circuit type
Max Integral Action on Room Control
Z1 Diagnostics
Room T
Room T setpoint
Flow temperature
Return temperature
Heat Request Z1
Pump Status
Z1 Zone Module Settings
Zone pump modulation
RANGE
0. Low temperature
1. High Temperature
0. Fix Flow T
1. Basic Thermoreg
2. Room T Only
3. Outdoor T Only
4. Room+Outdoor T
0. Radiator Fast
1,. Radiator Medium
2. Radiator Slow
3. Floor Heating Fast
4. Floor Heating Medium
5. Floor Heating Slow
6. Proportional only
ON - OFF
ON - OFF
0. Fixed speed
1. Modulating on delta T
2. Modulating on pressure
NOTE
HYD

Publicité