CHAFFOTEAUX EXPERT CONTROL Mode D'emploi page 116

Masquer les pouces Voir aussi pour EXPERT CONTROL:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

table of error codes
GB
ERROR
DESCRIPTION
Servicing scheduled
3
P9
Call Service Centre
3
08
ATM confi g. error
3
09
Gas relay error
3
11
Boiler error
3
12
Boiler error
4
01
Mdm-Bus com. err.
4
02
GPRS mdm error
4
03
Sim Card error
4
04
Mdm-P.C.B. com. err.
4
05
Mdm In1 error
4
06
Mdm In2 error
4
11
Z1 room sensor not available
4
12
Z2 room sensor not available
4
13
Z3 room sensor not available
4
14
Z4 room sensor not available
4
15
Z5 room sensor not available
4
16
Z6 room sensor not available
4
20
Bus power supply overload (
4
21
Boiler error
4
22
Boiler error
5
01
No fl ame
5
02
Flame without gas
5
04
Flame cut-off
5
P1
1 failed ignition
5
P2
2 failed ignition
5
P3
Flame cut-off
5
P4
Flame cut-off
5
10
Boiler error
5
11
6
01
Flue gas sensor err.
6
02
116
ERROR
DESCRIPTION
6
04
Low fan speed
6
05
Faulty fl ue gas sensor
6
07
Press. switch ON fan OFF
6
08
Press. switch OFF fan ON
6
09
Flue gas overheat
6
10
Exchange sensor open
6
12
Fan error
6
P1
Flue gas press. delay
6
P2
Flue gas press. opening
6
P4
Low fan speed
6
20
Boiler error
6
21
Boiler error
7
01
Faulty Z1 fl ow sensor
7
02
Faulty Z2 fl ow sensor
7
03
Faulty Z3 fl ow sensor
7
04
Faulty Z4 fl ow sensor
7
05
Faulty Z5 fl ow sensor
7
06
Faulty Z6 fl ow sensor
*
)
7
11
Faulty Z1 return sensor
7
12
Faulty Z2 return sensor
7
13
Faulty Z3 return sensor
7
14
Faulty Z4 return sensor
7
15
Faulty Z5 return sensor
7
16
Faulty Z6 return sensor
7
22
Zone 2 overheat
7
23
Zone 3 overheat
7
25
Zone 5 overheat
7
26
Zone 6 overheat
7
50
Hydraulics diagram not defi ned
7
51
Zone error
7
52

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

3318596

Table des Matières