Positioning
The device detects the room tempera-
ture, therefore several factors should be
taken into account when choosing an in-
stallation site.
Keep it away from sources of heat (radi-
ators, sunlight, fi replaces, etc.) and from
draughts, doorways and windows which
could affect the temperature readings.
It should be installed approximately 1.50
metres above the fl oor level.
Warning
Installation should be performed by a
qualifi ed technician.
Before fi tting the appliance, make sure
the electricity supply is not connected.
Wall installation
The EXPERT CONTROL system interface
must be fi tted to the wall before the BUS
line is connected.
- before connecting the wires to the
base of the system interface, slide the
tab protecting the connector and lift it
up (fi g. 1);
- connect the pair of wires to the con-
nector (as described on the follow-
ing page) and close the protective tab
again (fi g. 2);
- open up the holes required for fi xing;
- fi x the base of the device to the box on
the wall using the screws supplied in
the kit (fi g. 3);
- position the system interface on the
base, pushing it gently downwards
(fi g. 4).
fi g. 1
fi g. 2
GB
fi g. 3
fi g. 4
81