CHAFFOTEAUX EXPERT CONTROL Mode D'emploi page 117

Masquer les pouces Voir aussi pour EXPERT CONTROL:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

table of error codes
ERROR
DESCRIPTION
BUS communication error
9
01
Energy Manager
Separator fl ow sensor
9
02
Faulty
9
03
Faulty separator return sensor
9
04
Type 1 HP lock
9
05
HP evaporator sensor error
9
06
HP gas sensor error
9
07
HP HST sensor error
9
08
HP outdoor temp. sensor error
9
09
HP OMT sensor error
9
10
No communication with HYDI
9
11
Faulty HP pressure sensor (AC)
9
12
Faulty HP pressure sensor (DC)
9
13
Faulty HP fl ow sensor (AC)
9
14
Faulty HP fl ow sensor (DC)
9
15
Faulty HP condenser sensor
HP HYDI-ODU communication
9
16
error
9
17
Faulty HP return sensor
9
18
Type 2 HP lock
9
19
HP awaiting restart
9
20
Separator sensors error (fl ow+ret)
9
21
Electricity/gas cost ratio error
9
22
HP locked
9
23
Heating circuit pressure error
9
24
Error in communication with HP
9
25
No boiler
9
30
Energy Manager error
9
31
Energy Manager error
Restoring operation
If the system shuts down, a code will
appear on the system interface display
signalling the type of shutdown and the
reason behind it.
To restore normal operation, follow the
instructions provided on the display or, if
the error persists, contact an authorised
Technical Service Centre for assistance.
(*) BUS power supply overload
A BUS power supply overload error may
occur due to the connection of three or
more devices within the installed sys-
tem. Devices which may overload the
BUS network include:
- Multizone module
- Solar pump assembly
- Module for instant production of do-
mestic hot water
To avoid overloading the BUS power
supply, set microswitch 1 on one of the
P.C.B.s inside the equipment connected
to the system (except the boiler) to OFF,
as illustrated in the fi gure.
1
microswitch
ON
OFF
2
117
GB

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

3318596

Table des Matières