USAGE AND OPERATION

4.5. Parameter Table

Digit
meaning
Return water temp.
0
Setting(cooling mode)
Return water temp.
1
Setting(heating mode)
Turnround of dehumidifying
2
under heating mode frost
3
Defrosting start temperature
Terms of exit defrost under
4
heating model
time of exit defrost under
5
heating mode
6
System number
7
Automatic restarting
Model(cooling only/heat pump/
8
auxiliary electrical heating/hot
water
9
Water pump model
10
Fan mode
11
Fan type
*Remark:
Parameter 06:
1: means one system;
2: means two system.
Parameter 07:
0: the unit can not restart automatically
1: the unit can restart automatically
Parameter 08:
0: the mode of the unit is cooling only
1: the mode of the unit is heat pump
2: the mode of the unit is auxiliary electrical heating;
3: the mode of the unit is heating only.
Parameter 09:
0: always open.
1: 60 seconds start before compressors starting.
30 seconds stop after compressors stopping.
Parameter10:
0: low fan speed
1: high fan speed
2: automatic fan speed(high speed when air temperature is below 10 ,low speed when air
temperature is above 15 );
3: low fan speed during 9PM~8AM,high speed at other time;
4: automatic running according to above condition 2and 3.
default
Adjust(yes/no)
27 °C
yes
27 °C
yes
45MIN
yes
-7 °C
yes
13 °C
yes
8MIN
yes
1
yes
0
yes
3
yes
0
yes
3
yes
1
yes
11