Installation and servicing of air conditioning equipment can be hazardous due to internal refrigerant pressure
and live electrical components. Only trained and qualified service personnel should install or service this
equipment. Installation and service performed by unqualified persons can result in property damage, personal
injury, or death.
For SAFE operation this must be installed using only the approved exterior grille and wall sleeve accessories.
Failure to comply with this may result in property damage, personal injury, or death.
The installation of this appliance must conform to the requirements of the National Fire Protection Association;
the National Electrical Code, ANSI/NFPA No. 70 (latest edition) in the United States; the Canadian Electrical
Code part 1, CSA 22.1 (latest edition) in Canada; and any state or provincial laws or local ordinances. Local
authorities having jurisdiction should be consulted before installation is made. Such applicable regulations or
requirements take precedence over the general instructions in this manual.
1.1 DESCRIPTION
The DynaPack by Suburban Applied Products is a fully self-contained heating and cooling system that provides designers and builders
with a cost effective alternative to condition multiple rooms in a multi-unit housing application.
The DynaPack features:
1 to 2.5 Tons Cooling
36 – 60 Input MBTU GAS Heat
No Outside Condensing Unit
S Series – Standard – 80% TE
H Series – High Efficiency – 90%+ TE
R-410A Refrigerant
Insulated 16 GA Coated Steel Base Pan
Do not operate the unit during construction period; this may be a breach of the warranty conditions.

1.2 UNIT SPECIFICATIONS

MODEL
12AC3A036
BTU INPUT
36,000
VOLTS
208-230
AMPS
5.2
GAS CONNECTION
*MCA= Minimum Circuit Ampacity
MODEL
12AC3A039H 18AC3A039H 24AC3A052H 30AC3A052H
BTU INPUT
39,000
VOLTS
208-230
AMPS
4.7
GAS CONNECTION
*MCA= Minimum Circuit Ampacity
Suburban DynaPack S & H Series Owner's Manual 06/2020 Rev.2
HEATING
18AC3A036
24AC3A048
36,000
48,000
208-230
208-230
5.2
5.2
/
Inch Pipe at Unit
1
2
HEATING
39,000
52,000
208-230
208-230
4.7
4.7
/
Inch Pipe at Unit
1
2
WARNING
WARNING
CAUTION
Chapter 1: Description and Specifications
"S" Series
MODEL
30AC3A060
60,000
COOLING CAPACITY
208-230
VOLTS
5.2
WATTS
MCA*
REFRIGERANT CHARGE
REFRIGERANT
"H" Series
MODEL
COOLING CAPACITY
52,000
208-230
VOLTS
4.7
WATTS
MCA*
REFRIGERANT CHARGE
REFRIGERANT
2
COOLING
12AC3A036
18AC3A036
24AC3A048
12,000
18,000
24,000
208-230
208-230
208-230
1090
1636
2181
12.9
19.0
SEE INFORMATION STICKER ON UNIT
R410A
COOLING
12AC3A039H 18AC3A039H 24AC3A052H 30AC3A052H
12,000
18,000
24,000
208-230
208-230
208-230
1090
1636
2181
12.9
19.0
SEE INFORMATION STICKER ON UNIT
R410A
30AC3A060
29,500
208-230
2681
20.5
23.4
29,500
208-230
2681
20.5
23.4