After-Sales Service is at the disposal of the Skilled Technician to provide all necessary information.
WARNING
• Follow the connection instructions shown in the
• The motor pump power supply must comply with the data indicated on the plate (4): in particular, the power
voltage must not deviate by ± 10 % and the power source must be of a suitable power.
• If the power cable is too short, an extension cable may be used provided it is not longer than 5  m/16  ft and
that the cable section is at least 2.5  mm
• Ensure polarity in the connections (see also Figure 5):
red cable → positive (+);
black cable → negative (-).
• When connecting the motor pump to a battery, proceed as follows:
- if present, disconnect the earth cable;
- connect the red cable to the positive pole (+) of the battery;
- connect the black cable to the negative pole (-) of the battery;
- if present, reconnect the earth cable.
• When disconnecting the motor pump from a battery, proceed as follows:
- if present, disconnect the earth cable;
- disconnect the black cable from the negative pole (-) of the battery
- disconnect the red cable from the positive pole (+) of the battery;
- if present, reconnect the earth cable.
WARNING
• Follow the connection instructions shown in the
• The suction pipes must have a nominal pressure equal to 5 bar (73  psi).
• The delivery pipes must have a nominal pressure not below max. motor pump pressure.
• Do not tighten the suction and delivery fittings to a torque of more than 5  Nm (45  lbf in).
• All the pipes must be firmly fastened with clamps to the respective fittings.
For the hydraulic suction and delivery connections, refer to the following table and to Fig.  6, which
represents a generic diagram of a possible machine in which the motor pump is integrated.
a. Tank
b. Suction filter
c. Suction circuit
The connections to suction and delivery of the motor pump must be done according to the model
considering the couplings and minimum internal pipe diameters illustrated in the following table:
Model
EF 1200
EF 2200
EF 3000
EF 4000
EF 5500
EF 7000

POWER CONNECTION

2
<AWG  14> (EF 7000 - 12V 4 mm

HYDRAULIC CONNECTION

d. Motor pump
e. Delivery circuit
f. Spray lance (example of accessory)
Coupling
hose holder Ø 10 mm (3/8")
3/8 NPT female
1/2 NPT female
"s
pecIFIcatIons and technIcaL data
"s
pecIFIcatIons and technIcaL data
Minimum internal pipe diameter
10 mm (3/8")
13 mm (1/2")
19 mm (3/4")
" paragraph " .
2
<AWG 12>).
" paragraph.