WARNING
• The pressure switch is calibrated by the motor pump Manufacturer. Do not attempt to alter the settings.
b) Protection fuse.
This device stops the motor pump from working in case of excessive absorption.
If one of these trips, proceed as follows, keeping to the indications shown in the manual of the machine
in which the motor pump is integrated:
• stop the machine and disconnect the power supply;
• release any residual pressure in the high-pressure circuit;
• replace the fuse with another suitable one (refer also to the paragraph
";
data
• make sure the instructions have been followed in the paragraph
" ;
poweR suppLy
• connect the power supply again and repeat the start procedure.
WARNING
• In case these safety devices trip frequently, do not use the motor pump (and therefore the machine in which
it is integrated) without first having it checked by a Skilled Technician.
WARNING
• The motor pump must not be run by itself. It is only meant to be integrated in a machine.
• The motor pump must be integrated in machines used for the following purposes:
- crop spraying and protection in agriculture and gardening;
- pumping detergents and colours in aqueous solution;
- pumping water for non-edible use;
- transfer of non-viscous liquids.
• The motor pump must not be integrated in machines for pumping:
- solutions of chemical products the compatibility of which with the materials making up the motor pump
itself is not known (polypropylene, Viton®, stainless steel, Santoprene™);
- fuels of all kinds and types;
- inflammable liquids or liquefied gases;
- edible liquids;
- solvents and thinners of all kinds and types;
- paints of all kinds and types;
- liquids containing granules or solid parts in suspension.
• The motor pump must not be integrated in machines designed to wash: people, animals, energized electrical
apparatus, delicate objects, the motor pump itself or the machine in which it is integrated.
• The motor pump is not suitable for being integrated in machines designed to operate in environments with
special conditions such as, for example, corrosive or explosive atmospheres.
• For integration in machines designed to operate on board vehicles, ships or planes, contact the Manufacturer's
Technical After-Sales Service, inasmuch as additional requirements may be necessary.
All other uses are to be deemed incorrect.
The Manufacturer disclaims all liability for any damage deriving from incorrect or erroneous uses.
WARNING
• The motor pump cannot be operated unless the machine in which it is integrated conforms to the
safety requirements laid down by European Directives. Such conformity is indicated by
and by the declaration of conformity of the Manufacturer of the machine in which the motor pump