Operation

Connecting the Control Device (Thermostat)

1. Uncouple the terminals (A) attached to the tips of the white
wires coming out of the right side of the burner cover.
2. Connect both the male and female terminals, which are
uncoupled, to the connectors (B) of the control device.
• If the heater is controlled by another device (such as a thermostat or a timer), the heater could turn
itself on at any time.
• When the heater is controlled by another device, extra care must be taken to ensure that the
heater is not accidentally turned on without someone nearby who can immediately attend to any
problems when the heater is ignited, operating, and cooling off.

Heat Shielding Mat

To avoid unexpected fire or trouble, NEVER use the heater on
combustible flooring unless the heat shielding mat, which is
available as an option, is used.

Operation with Portable Generator

Before operating the heater from a portable generator, please confirm that the generator has been
properly connected to the ground earth. Operating the generator without proper grounding may result
in electrical shock. Please refer to the owner's manual supplied by the manufacturer of the generator.
The heater operates within the voltage range between 108 Volts and 132 Volts. Before plugging the heater into the
generator, the output voltage of the generator should be verified.
If the voltage does not measure in this range, the heater should not be plugged into the generator.

Maintenance

• Do not repair or service the heater if you have not been trained in repair and service of natural and
propane gas heaters. Maintenance should only be carried out by authorized persons.
• To avoid any injury and/or trouble, never inspect or service the heater while it is burning, in
operation, hot or plugged-in.
• Make sure to close all gas supply valves before service of heater unit.