INFRARED GAS HEATER
• This Owner's Manual provides important information on proper handling, operation,
and maintenance. FAILURE TO FOLLOW THE INSTRUCTIONS, PRECAUTIONS,
OR SAFETY TIPS IN THIS MANUAL AUTOMATICALLY VOIDS ALL WARRANTIES,
EXPRESS OR IMPLIED.
• FAILURE TO COMPLY WITH THE INSTRUCTIONS, PRECAUTIONS, AND
SAFETY TIPS IN THIS MANUAL CAN RESULT IN DEATH, SERIOUS BODILY
INJURY AND PROPERTY LOSS OR DAMAGE FROM HAZARDS OF FIRE,
EXPLOSION, BURN, ASPHYXIATION, CARBON MONOXIDE POISONING, AND /
OR ELECTRICAL SHOCK.
• Read and thoroughly understand this Owner's Manual before using the heater in
any way, including unpacking, assembling, fueling, inspecting, lighting, operating,
adjusting, turning off, cooling down, moving, or storing the heater.
• Please keep this Manual for the user's need and reference.
• Do not allow anyone who has not read and understood this Owner's Manual to
assemble, inspect, light, operate, adjust, turn off, cool down, refuel, move, or store
the heater.
• The requirements of local authorities having jurisdiction shall be followed.
• The installation of the unit shall be in accordance with the regulations of the
authorities having jurisdiction.
IMPORTANT

Publicité

Chapitres

Table des Matières
loading

Sommaire des Matières pour Shizuoka Seiki Co. VAL6 GN5

  • Page 1 INFRARED GAS HEATER IMPORTANT • This Owner’s Manual provides important information on proper handling, operation, and maintenance. FAILURE TO FOLLOW THE INSTRUCTIONS, PRECAUTIONS, OR SAFETY TIPS IN THIS MANUAL AUTOMATICALLY VOIDS ALL WARRANTIES, EXPRESS OR IMPLIED. • FAILURE TO COMPLY WITH THE INSTRUCTIONS, PRECAUTIONS, AND SAFETY TIPS IN THIS MANUAL CAN RESULT IN DEATH, SERIOUS BODILY INJURY AND PROPERTY LOSS OR DAMAGE FROM HAZARDS OF FIRE, EXPLOSION, BURN, ASPHYXIATION, CARBON MONOXIDE POISONING, AND /...
  • Page 2 GENERAL HAZARD WARNING: FAILURE TO COMPLY WITH THE PRECAUTIONS AND INSTRUCTIONS PROVIDED WITH THIS HEATER, CAN RESULT IN DEATH, SERIOUS BODILY INJURY AND PROPERTY LOSS OR DAMAGE FROM HAZARDS OF FIRE, EXPLOSION, BURN, ASPHYXIATION, CARBON MONOXIDE POISONING, AND / OR ELECTRICAL SHOCK.
  • Page 3 Important Manual Information To the owner Thank you for choosing a Shizuoka Seiki infrared gas heater. This Owner’s Manual contains information needed for proper operation, maintenance and care. A thorough understanding of these simple instructions will help you obtain maximum satisfaction from your new Shizuoka Seiki. If you have any questions about the operation or maintenance of your infrared gas heater, please consult with your Shizuoka Seiki dealer.
  • Page 4 • This Manual aims to supply the user with detailed information on how to properly use, operate and service this VAL6 Heater. • The VAL6 GN5, VAL6 GP5, and the standard equipment are used as the basis for explanations, pictures, and illustrations in this manual.
  • Page 5: Table Des Matières

    Table of Contents Location of Safety Labels ................1 Safety Information ..................3 Specifications ....................8 Heater Specifications ....................8 Gas Requirement ......................8 Wiring Diagram ......................8 Main Components ..................9 Safety Devices .....................10 Operation ......................10 Gas Cylinder Installation .................... 10 Hose Connection ....................... 10 Check Leakage ......................11 Gas Cylinder Numbers for Operation ................11 Adjust the Angle of Main Unit ..................
  • Page 6: Location Of Safety Labels

    Location of Safety Labels • Safety labels provide important information for safe use of the heater. Do not remove or soil them. • If any labels are illegible or have been removed, contact your dealer for replacements. (3) Hot surface warning label (4) Danger/warning/caution label (1) Danger/warning labels (5) Specification label...
  • Page 7 Location of Safety Labels (3) Hot surface warning label (4) Danger/warning/caution label (5) Specification labels    SERIAL NO. is required for consulting with your dealer.
  • Page 8: Safety Information

    These precautions must also be followed thereafter. Use proper gas for the heater as described below. Use proper gas VAL6 GN5 = Natural GAS for the heater VAL6 GP5 = Propane GAS Check the specifications on your heater before using the heater.
  • Page 9 Safety Information Do not use the Never use the heater at an altitude higher than 3,000 ft. (1,000 m) above sea heater at high level as this may cause production of carbon monoxide by the heater due to insufficient oxygen. altitudes Follow all When operating or servicing this heater, please follow all instructions...
  • Page 10 Safety Information Keep flammable To prevent fires, please keep all flammables more than 8.2 ft. (2.5 m) away materials away from the front of the radiation disk, and more than 6.6 ft. (2 m) away from all from the heater sides (left/right and top/rear) of the heater.
  • Page 11 Safety Information Make sure the flame is After shutting off the heater, make sure that the flame is extinguished and the extinguished and power disconnected before leaving the heater unattended. It is also not safe the power off to leave the heater unattended while it is cooling off or to leave it in any area before leaving where children are present or could come near the heater.
  • Page 12 Safety Information Arrange for the The cylinder supply system should be arranged for in order provide vapor cylinder supply withdrawal from the operating cylinder. system Be sure to shut off the gas supply The gas should be turned off at gas supply cylinder/line when the heater is not when not using in use.
  • Page 13: Specifications

    Specifications Heater Specifications VAL6 GN5 VAL GP5 Radiated direct flame Type Ignition System High intensity discharge Fuel Natural gas Propane gas Fuel Consumption 137 CFH / 6.1 lbs/h 55.8 CFH / 6.6 lbs/h Heat Output 144,000 BTU/h / 42.2 kW Dimensions (H×D×W)
  • Page 14: Main Components

    Main Components 1 Radiation disk 5 Burner grip 9 Blower 2 Protector 6 Burner cover 10 Tip-over switch 3 Wheel 7 Switch section 11 Legs 4 Knob bolt 8 Handle Switch Section Burner Section 15 19 12 Air switch 16 Fuse 20 Operating switch 13 Solenoid valve 17 Overheat protection...
  • Page 15: Safety Devices

    Safety Devices Description of Safety Devices Automatically extinguishes the flame if the heater overheats. Operating condition: Misfire lamp lights and the post purge sequence runs for Overheat protection about 5 minutes if the heater is in operation. This shuts off the power supply in case of excessive electric current due to Electric overload system (Fuse) problems with the devices.
  • Page 16: Check Leakage

    Operation Check Leakage • Check all connections for leaks. Apply a soap and water solution to all connections and check for bubbles. If any leaks are detected, retightening of connections is required immediately. • Shut off the gas supply valve before refastening the connections. •...
  • Page 17: Adjust The Angle Of Main Unit

    Operation Adjust the Angle of Main Unit • To avoid severe burns and electrical shock, do not adjust the angle of the main unit while the heater is plugged in, operating, or hot. • To avoid major burn injury, be sure to take hold of the burner grip when setting the angle of the main unit.
  • Page 18: Operation Procedures

    Operation Operation Procedures • If you detect smoke or a burning smell coming from the heater, turn the heater off immediately to prevent a fire, and contact your dealer to have the heater inspected prior to further operation. • If the heater does not ignite the first time, do not try to ignite more than 2 more times in a row thereafter, as this could result in a fire.
  • Page 19: Connecting The Control Device (Thermostat)

    Operation Connecting the Control Device (Thermostat) Terminals (A) 1. Uncouple the terminals (A) attached to the tips of the white wires coming out of the right side of the burner cover. 2. Connect both the male and female terminals, which are uncoupled, to the connectors (B) of the control device.
  • Page 20: Storage

    Maintenance • Before starting any inspection or service, to avoid electrical shock, please make sure the heater is shut down and that the power cord is disconnected. • When cleaning the heater, please wear gloves to prevent possible injury. • Do not use a pressure washer for cleaning the heater. 1.
  • Page 23: Warranty Policy

    VAL6 Series Heaters by SHIZUOKA SEIKI WARRANTY POLICY VAL6 Infrared Heater series SHIZUOKA SEIKI warrants that its heaters and component parts will be free from defects in material and workmanship for a period of 24 months from date of purchase, when properly installed, operated, and maintained in accordance with the installation and Maintenance Instructions, safety guides and labels contained with each unit.
  • Page 24: User Registration

    USER REGISTRATION Please enter the following temporary ID & Password and complete the user registration form on our website. By completing your registration, you will obtain your own ID & Password. This allows you to download the owner’s manual and/or parts list from our website.
  • Page 25: Appareil De Chauffage Infrarouge Au Gaz

    APPAREIL DE CHAUFFAGE INFRAROUGE AU GAZ IMPORTANT • Ce manuel d’utilisation fournit des informations importantes sur la manipulation, l’utilisation et l’entretien de l’appareil. L’INOBSERVATION DES INSTRUCTIONS, PRÉCAUTIONS ET CONSIGNES DE SÉCURITÉ MENTIONNÉES DANS CE MANUEL REND CADUQUES TOUTES LES GARANTIES, QU’ELLES SOIENT EXPRESSES OU IMPLICITES. •...
  • Page 26 MISES EN GARDE GÉNÉRALES: LE NON-RESPECT DES MISES EN GARDE ET DES INSTRUCTIONS FOURNIES AVEC CE RADIATEUR PEUT ENTRAÎNER LA MORT, DE GRAVES BLESSURES ET DES PERTES MATÉRIELLES OU DES DOMMAGES À LA PROPRIÉTÉ RÉSULTANT D’UN INCENDIE, D’UNE EXPLOSION, DE BRÛLURES, D’ASPHYXIE, D’EMPOISONNEMENT AU MONOXYDE DE CARBONE ET/OU D’UN CHOC ÉLECTRIQUE.
  • Page 27 Informations importantes du manuel À l’attention de l’utilisateur Merci d’avoir choisi cet appareil de chauffage infrarouge au gaz de Shizuoka Seiki. Le présent manuel d’instructions contient des informations nécessaires à l’utilisation, la maintenance et l’entretien adéquats. La parfaite compréhension de ces instructions simples vous aidera à tirer pleinement satisfaction de votre nouvel appareil Shizuoka Seiki.
  • Page 28 • Ce manuel a pour but de fournir à l’utilisateur des informations détaillées sur la façon adéquate d’utiliser, de faire fonctionner et d’entretenir cet appareil de chauffage VAL6. • Les explications, photos et illustrations de ce manuel sont basées sur le VAL6 GN5, le VAL6 GP5 et l’équipement standard.
  • Page 29 Table des matières Emplacement des étiquettes de sécurité ............1 Informations de sécurité ................3 Caractéristiques techniques ................8 Caractéristiques techniques de l’appareil ..............8 Exigences relatives au gaz ..................8 Schéma de câblage ..................... 8 Principaux composants ................9 Dispositifs de sécurité ................10 Fonctionnement ...................10 Installation du cylindre de gaz ..................
  • Page 30: Emplacement Des Étiquettes De Sécurité

    Emplacement des étiquettes de sécurité • Les étiquettes de sécurité fournissent des informations importantes à propos d’une utilisation sûre de l’appareil de chauffage. Par conséquent, veuillez ne pas les retirer ni les souiller. • Si des étiquettes deviennent illisibles ou se sont décollées, contactez votre revendeur pour obtenir des étiquettes de rechange.
  • Page 31 Emplacement des étiquettes de sécurité (3) Étiquette de précaution relative à une surface chaude (4) Étiquette relative à la chaleur (5) Étiquette des caractéristiques techniques   Vous devrez indiquer le NUMÉRO DE SÉRIE au revendeur. ...
  • Page 32: Informations De Sécurité

    Ces précautions doivent ensuite être respectées à la lettre. Utilisez le bon type de gaz avec l’appareil, tel qu’indiqué ci-dessous. Utilisez le bon VAL6 GN5 = GAZ naturel type de gaz avec VAL6 GP5 = GAZ propane l’appareil...
  • Page 33 Informations de sécurité Prévention des Pour éviter un incendie ou un accident inattendu, ne mettez jamais quoi que incendies ce soit sur le disque de rayonnement et sur le protecteur. N’utilisez pas N’utilisez jamais l’appareil à une altitude supérieure à 1 000 mètres (3 000 l’appareil de pieds) au-dessus du niveau de la mer, car cela peut causer la production de chauffage à...
  • Page 34 Informations de sécurité Cet appareil est pour une utilisation industrielle uniquement. N’utilisez jamais N’utilisez jamais l’appareil pour cet appareil pour quelque application résidentielle que ce soit. Une utilisation une application incorrecte peut entraîner un risque potentiel de mort, de blessures graves, résidentielle d’incendie et/ou d’explosion.
  • Page 35 Informations de sécurité Ne déplacez pas Déplacer l’appareil quand il est en fonctionnement est interdit. Tout l’appareil pendant déplacement peut provoquer un incendie, tout particulièrement si l’appareil qu’il est en venait à être renversé ou déséquilibré. fonctionnement Arrêtez l’appareil Avant de débrancher la fiche du cordon d’alimentation, assurez-vous que le avant de le témoin de fonctionnement est éteint.
  • Page 36 Informations de sécurité N’utilisez pas Assurez-vous d’utiliser l’appareil à des températures comprises entre -10 l’appareil par des ºC et 30 ºC (14 ºF et 86 ºF). Si l’appareil est utilisé à plus de 30 ºC (86 ºF), il températures surchauffera et risquera de provoquer un incendie. extrêmes Fournissez le manuel...
  • Page 37: Caractéristiques Techniques

    Caractéristiques techniques Caractéristiques techniques de l’appareil VAL6 GN5 VAL GP5 Type Brûleur à rayonnement direct Système d’inflammation de combustible Décharge à haute intensité Combustible Gaz naturel Gaz propane Consommation de combustible 137 CFH / 6,1 lbs/h 55,8 CFH / 6,6 lbs/h Chaleur produite 144.000 BTU/h / 42,2 kW...
  • Page 38: Principaux Composants

    Principaux composants Disque de rayonnement Poignée de brûleur Soufflante Protecteur Couvercle de protection de brûleur 10 Contacteur de renversement Roue Section commutateur 11 Pieds Boulon moleté Poignée Section brûleur Section commutateur 15 19 12 Commutateur d’air 16 Fusible 20 Commutateur de fonctionnement 13 Électrovanne 17 Protection contre la surchauffe 21 Lampe témoin de fonctionnement...
  • Page 39: Dispositifs De Sécurité

    Dispositifs de sécurité Description des dispositifs de sécurité Elle provoque l’extinction de la flamme en cas de surchauffe. Condition de fonctionnement : La lampe témoin de ratés d’allumage s’allume Protection contre la surchauffe et la purge est réalisée pendant environ 5 minutes si l’appareil est en fonctionnement.
  • Page 40: Vérification Des Fuites

    Fonctionnement Vérification des fuites • Vérifiez l’absence de fuites sur toutes les connexions. Appliquez une solution d’eau savonneuse sur toutes les connexions et vérifiez s’il y a des bulles. Si vous détectez des fuites, resserrez immédiatement les connexions. • Fermez la vanne d’alimentation en gaz avant de resserrer les connexions. •...
  • Page 41: Ajustez L'angle D'orientation De L'appareil Principal

    Fonctionnement Ajustez l’angle d’orientation de l’appareil principal • Ne réglez pas l’angle de l’appareil quand il est relié au secteur, qu’il fonctionne ou qu’il est chaud car vous vous exposez à des brûlures ou des décharges électriques. • Pour éviter de subir une grave blessure, pensez à saisir l’appareil par la poignée de brûleur lorsque vous ajustez l’angle.
  • Page 42: Procédures D'utilisation

    Fonctionnement Procédures d’utilisation • Si une odeur de brûlé ou de la fumée se dégagent de l’appareil, arrêtez-le immédiatement et consultez le revendeur pour qu’il l’inspecte avant toute remise en service. • Si l’appareil ne s’allume pas dès la première tentative, ne faites pas plus de 2 autres tentatives, faute de quoi vous vous exposez à...
  • Page 43: Connexion Du Dispositif De Commande (Thermostat)

    Fonctionnement Connexion du dispositif de commande (Thermostat) Bornes (A) 1. Détachez les bornes (A) fixées aux extrémités des fils blancs qui sortent du côté droit du couverle de brûleur. 2. Branchez les bornes mâle et femelle, qui sont séparées, aux connecteurs (B) du dispositif de commande.
  • Page 44: Rangement

    Maintenance • Avant de commencer tout travail d’inspection ou de maintenance, évitez les décharges électriques en vous assurant que l’appareil est arrêté et que son cordon d’alimentation est débranché. • Lorsque vous nettoyez l’appareil, portez des gants pour éviter les risques de blessure. •...
  • Page 47: Garantie

    SHIZUOKA SEIKI, Appareils de chauffage, série VAL6 GARANTIE Appareils de chauffage à infrarouge, série VAL6 SHIZUOKA SEIKI garantit que ses appareils de chauffage et les pièces qui entrent dans leur fabrication sont dépourvus de défauts de matière et de main d’œuvre pendant une période de 24 mois à compter de la date d’achat, sous réserve qu’ils soient installés, utilisés et entretenus conformément aux instructions d’installation et d’entretien, aux consignes de sécurité...
  • Page 48: Enregistrement De L'utilisateur

    Enregistrement de l’utilisateur Veuillez entrer l’identifiant et le mot de passe temporaires suivants et remplir le formulaire d’enregistrement de l’utilisateur sur notre site Web. En Faisant cela, vous pourrez obtenir un identifiant et un mot de passer personnalisé. Cela vous permettra de télécharger le mode d’emploi et/ou la liste des pièces détachées à...
  • Page 49 IMPORTANT • This Owner’s Manual provides important information on proper handling, operation, and maintenance. FAILURE TO FOLLOW THE INSTRUCTIONS, PRECAUTIONS, OR SAFETY TIPS IN THIS MANUAL AUTOMATICALLY VOIDS ALL WARRANTIES, EXPRESS OR IMPLIED. • FAILURE TO COMPLY WITH THE INSTRUCTIONS, PRECAUTIONS, AND SAFETY TIPS IN THIS MANUAL CAN RESULT IN DEATH, SERIOUS BODILY INJURY AND PROPERTY LOSS OR DAMAGE FROM HAZARDS OF FIRE, EXPLOSION, BURN, ASPHYXIATION, CARBON MONOXIDE POISONING, AND / OR ELECTRICAL SHOCK. • Read and thoroughly understand this Owner’s Manual before using the heater in any way, including unpacking, assembling, fueling, inspecting, lighting, operating, adjusting, turning off, cooling down, moving, or storing the heater.
  • Page 50 GENERAL HAZARD WARNING: FAILURE TO COMPLY WITH THE PRECAUTIONS AND INSTRUCTIONS PROVIDED WITH THIS HEATER, CAN RESULT IN DEATH, SERIOUS BODILY INJURY AND PROPERTY LOSS OR DAMAGE FROM HAZARDS OF FIRE, EXPLOSION, BURN, ASPHYXIATION, CARBON MONOXIDE POISONING, AND / OR ELECTRICAL SHOCK. ONLY PERSONS WHO CAN UNDERSTAND AND FOLLOW THE INSTRUCTIONS SHOULD USE OR SERVICE THIS HEATER. IF YOU NEED ASSISTANCE OR HEATER INFORMATION SUCH AS AN INSTRUCTIONS MANUAL, LABEL, ETC. CONTACT THE MANUFACTURER. FIRE, BURN, INHALATION, AND EXPLOSION HAZARD. KEEP SOLID COMBUSTIBLES, WARNING: SUCH AS BUILDING MATERIALS, PAPER OR CARDBOARD, A SAFE DISTANCE AWAY FROM THE HEATER AS RECOMMENDED BY THE INSTRUCTIONS. NEVER USE THE HEATER IN SPACES WHICH DO OR MAY CONTAIN VOLATILE OR AIRBORNE COMBUSTIBLES. OR PRODUCTS SUCH AS GASOLINE, SOLVENTS, PAINT THINNER, DUST PARTICLES OR UNKNOWN CHEMICALS.
  • Page 51 Important Manual Information To the owner Thank you for choosing a Shizuoka Seiki infrared gas heater. This Owner’s Manual contains information needed for proper operation, maintenance and care. A thorough understanding of these simple instructions will help you obtain maximum satisfaction from your new Shizuoka Seiki. If you have any questions about the operation or maintenance of your infrared gas heater, please consult with your Shizuoka Seiki dealer. If you have any questions or want to know more detailed information about the heater, please contact your dealer. If any irregular or missing pages are found in this Manual, please contact your dealer and we will replace them with new ones. In this Owner’s Manual, particularly important information is distinguished in the following ways. “DANGER” means that failure to follow the given precaution (s) may lead to death, serious injury and/or major fire. “WARNING” means that failure to follow the given precaution (s) may likely result in death, serious injury, fire and/or possible explosion. “CAUTION” means that failure to follow the given precaution (s) may result in serious injury and/or property damage. Depending on the circumstances, even the category of “CAUTION” can lead to grave damage to persons and/or property. Cautions and recommendations listed in each category are equally important for safe operation. Be sure to follow the precautions in all 3 categories. POINT: A POINT provides key information to simplify and clarify procedures. The following signs, used throughout this Manual, are defined as follows: Prohibited (This indicates “actions that are strictly forbidden”.) Mandatory (This indicates “actions or instructions” that must be carried out.) Caution (This indicates “actions” that require careful attention) AS we cannot predict every possible dangerous situation while operating this heater, the contents described in this Manual cannot fully foresee the entire range of possible dangers. When operating the heater or carrying out daily inspection, please pay careful attention to the contents of this Manual and the Labels on the heater itself. In addition, be constantly alert for factors that might affect the safe operation of the heater. Do not hesitate to stop operation and contact your dealer if you have any questions about any matters not discussed in this Manual.
  • Page 52 Important Manual Information • Intended use is the temporary heating of buildings or structures under construction, alteration or repair. • The installation shall conform with local codes or, in the absence of local codes, with the National Fuel Gas Code ANSI Z223.1/NFPA 54 and the Natural Gas and Propane Installation Code, CSA B149.1. • The installation must conform with local codes or in the absence of local codes, with the Standard for the Storage and Handling of Liquefied Petroleum Gases, ANSI/NFPA 58 and the Natural Gas and Propane Installation Code, CSA B149.1. Shizuoka Seiki is constantly striving to improve product design and quality. Therefore, although this manual contains the most current product information available at the time of printing, there may be minor discrepancies between your heater and this manual. If you have any questions concerning this manual, please consult your Shizuoka Seiki dealer.
  • Page 53 Table of Contents Location of Safety Labels ................1 Safety Information ..................3 Specifications ....................8 Heater Specifications ....................8 Gas Requirement ......................8 Wiring Diagram ......................8 Main Components ..................9 Safety Devices .....................10 Operation ......................10 Gas Cylinder Installation .................... 10 Hose Connection ....................... 10 Check Leakage ......................11 Gas Cylinder Numbers for Operation ................11 Adjust the Angle of Main Unit ..................12 Connecting the Power Supply .
  • Page 54: Location Of Safety Labels

    Location of Safety Labels • Safety labels provide important information for safe use of the heater. Do not remove or soil them. • If any labels are illegible or have been removed, contact your dealer for replacements. (3) Hot surface warning label (1) Danger/warning labels (2) Danger/warning/ caution label (4) Specification label (5) Wiring diagram label (1) Danger/warning labels (2) Danger/warning/caution label Read Owner's Manual before using. GENERAL HAZARD WARNING: •...
  • Page 55 Location of Safety Labels (3) Hot surface warning label (4) Specification labels VAL6GP5II SERIAL NO. is required for consulting with your dealer.  (5) Wiring diagram label...
  • Page 56: Safety Information

    Safety Information To Help Ensure Safe Operation, Comply with the Following Precautions It is important that the safety precautions listed below are understood and followed prior to initial operation of the heater. These precautions must also be followed thereafter. Use proper gas for the heater as described below. Use proper gas VAL6 GP5II = Propane GAS for the heater Check the specifications on your heater before using the heater. Use of Never use or store the heater where thinner, gasoline, liquid propane gas, or flammables other highly flammable vapors, etc., are present, because these may lead to prohibited explosion or fire. Never use the heater in poorly ventilated areas. Poor ventilation allows a buildup of carbon monoxide produced by the heater, especially if there is also inadequate combustion. CARBON MONOXIDE is a colorless and odorless poisonous gas that can cause death or injury. Always provide a fresh supply of external or circulating air whenever the heater is being used.
  • Page 57 Safety Information Follow all When operating or servicing this heater, please follow all instructions instructions in described in this Manual. Owner’s Manual When replacing parts, use only the genuine parts made or approved by Use only genuine Shizuoka Seiki. Please note that we shall not be held responsible or liable parts for any damage or accident that results from using any unapproved or non- genuine parts. We shall not be held liable or responsible for any damage or accident that Liability or results from disobeying or not properly carrying out any instructions in this responsibility Manual, or from the improper modification or operation of the heater. Keep aerosol Never place sealed, pressurized containers (such as aerosol cans) near the containers away heater as exposure to heat from the heater may build up pressure in the...
  • Page 58 Safety Information Keep flammable To prevent fires, please keep all flammables more than 8.2 ft. (2.5 m) away materials away from the front of the radiation disk, and more than 6.6 ft. (2 m) away from all from the heater sides (left/right and top/rear) of the heater. To prevent fires, never place any object within 3.3 ft. (1 m) from (the front of) Do not block the the radiation disk. The flow of combustion and ventilation air should not be heater obstructed. Do not try to If the heater does not ignite the first time, do not try to ignite more than 2 ignite the heater more times in a row thereafter, as this could result in a fire. If the heater does more than 3 times not ignite after the third attempt, make no further attempts and consult your in a row dealer prior to further operation of the heater. Do not operate In order that unexpected problems, such as fire, can be dealt with the heater immediately, do not leave the heater unattended while it is in operation or unattended...
  • Page 59 Safety Information Make sure the flame is After shutting off the heater, make sure that the flame is extinguished and the extinguished and power disconnected before leaving the heater unattended. It is also not safe the power off to leave the heater unattended while it is cooling off or to leave it in any area before leaving where children are present or could come near the heater. the heater unattended Do not dispose When disposing of the heater, please do not dispose of it illegally, but consult of the heater your local authorities or specialists on how to properly dispose of it. illegally To prevent accident or injury, do not use the heater in the following places or under the following conditions: • On vibrating, trembling, or unstable flooring • On ladders, scaffolds, or sawhorses Do not use the • On any floor that is slanted, sloped, or not level heater in the • On stairs or anywhere where it might block access to emergency exits following places • Near unstable or stacked materials or conditions • In windy, humid, or dusty areas, and areas where metal particles are present • In areas where the flow of people or vehicles is impeded or obstructed Always use caution in determining where to place the heater for use or storage and take into account both present and potential future dangers.
  • Page 60 Safety Information The heater, other than a heater with an integral propane gas container, must Keep the heater be located at least: (i) 6 ft. (1.83 m) in the U.S. or (ii) 10 ft. (3 m) in Canada, away from from any propane gas container. propane gas Each heater shall be supplied with a gas hose assembly neither less than 15 containers ft (5 m) nor more than 50 ft (16 m) in total length in Canada. And neither less than 10 ft (3 m) nor more than 25 ft (8 m) in total length in US. Pay attention to Blower or radiant type heaters shall not be directed toward any propane-gas direction of heater container within 20 ft. (6 m). Arrange for the The cylinder supply system should be arranged for in order provide vapor cylinder supply withdrawal from the operating cylinder. system Be sure to shut off the gas supply The gas should be turned off at gas supply cylinder/line when the heater is not when not using in use. heater Be sure to If the heater is to be stored indoors, the connection between the propane disconnect the supply cylinder and the heater must be disconnected, and the cylinder cylinder and...
  • Page 61: Specifications

    Specifications Heater Specifications VAL6 GP5II Type Radiated direct flame Ignition System High intensity discharge Fuel Propane gas Fuel Consumption 50.5 CFH / 6.0 lbs/h Heat Output 122,000 BTU/h / 35.8 kW Dimensions (H×D×W) 35.3 x 31.7 x 30.3 inch / 896 x 804 x 770 mm Dry Weight 110.2 lbs / 50 kg Power Supply 120 V 60 Hz When igniting: 97 W Power Consumption When burning: 81 W Fuse Type 3.0 A Noise Level 60 dB (A) Flame monitor (Flame-rod) Safety Systems Overheat protection × 2 Tip-over switch Accessory Hose Gas Requirement GP5II (Propane gas) Max. 11.0 IN. WC. Inlet pressure Min. 10.0 IN. WC.
  • Page 62: Main Components

    Main Components 1 Radiation disk 6 Burner grip 11 Tip-over switch 2 Protector 7 Burner cover 12 Legs 3 Wheel 8 Switch section 13 Filter 4 Casing overheat sensor 9 Handle 14 Nipple 5 Knob bolt 10 Blower Burner Section Switch Section 15 Gas/Air Ratio control Gas Valve 19 Mixer overheat sensor 16 Fuse 20 Operating switch 17 Ignition transformer 21 Operating lamp 18 Combustion fan 22 Misfire lamp...
  • Page 63: Safety Devices

    Safety Devices Description of Safety Devices Automatically extinguishes the flame if the heater overheats. Casing overheat protection Operating condition: Misfire lamp lights and the post purge sequence runs for about 5 minutes if the heater is in operation. This shuts off the power supply in case of excessive electric current due to Electric overload system (Fuse) problems with the devices. Operating condition: The entire operation stops. Automatically extinguishes the flame when motion or an impact is detected during operation. Tip-over switch Operating condition: Misfire lamp lights and the post purge sequence runs for about 5 minutes if the heater is in operation. Automatically extinguishes the flame if the heater overheats. Mixer overheat protection Operating condition: Misfire lamp lights and the post purge sequence runs for about 5 minutes if the heater is in operation. Operation Gas Cylinder Installation POINT: • The installation must conform with local codes or, in the absence of local codes, with the Standards for the Storage and Handling of Liquefied Petroleum Gases, ANSI/NFPA 58 and the Natural Gas and Propane Installation Code, CSA B149.1. • Regulator must be installed at outlet of cylinder of propane gas and input gas pressure have to be 11" w.c. Hose Connection • All hose connections must be made using a wrench to tighten the fitting. • Be sure that the cylinder valve is closed when connecting or disconnecting the cylinder.
  • Page 64: Check Leakage

    Operation Check Leakage • Check all connections for leaks. Apply a soap and water solution to all connections and check for bubbles. If any leaks are detected, retightening of connections is required immediately. • Shut off the gas supply valve before refastening the connections. • After repairing the leaks, retry to check connections for leaks with a soap and water solution. Do not touch or adjust a brass pipe on solenoid valve. This is intended for maintenance person to check the manifold pressure. If it is made any adjustment improperly, gas leakage may occur. Gas Cylinder Numbers for Operation Vaporization Rate 100 LB Propane Cylinders (approximate) Maximum continuous draw in BTU per hour at various temperatures expressed in Fahrenheit. This heater cannot be used at less than 122,000 BTU, thus keep supplied amount at over 122,000. 20 degree F (-6.7 ºC) Lbs. of Propane in Cylinder 1 Tank 2 Tanks 3 Tanks 167,000 367,000...
  • Page 65: Adjust The Angle Of Main Unit

    Operation Adjust the Angle of Main Unit • To avoid severe burns and electrical shock, do not adjust the angle of the main unit while the heater is plugged in, operating, or hot. • To avoid major burn injury, be sure to take hold of the burner grip when setting the angle of the main unit. Prior to operation, loosen the knob bolt to move and Radiation disk set the main heater unit at the desired angle, and then tighten the knob bolt firmly. The vertical angle of the radiation disk is adjustable up to 90 degrees. Knob bolt Loosen Tighten Connecting the Power Supply Do not use an adapter to change the power plug or power outlet from grounded (3 prongs or inlets)
  • Page 66: Operation Procedures

    Operation Operation Procedures • If you detect smoke or a burning smell coming from the heater, turn the heater off immediately to prevent a fire, and contact your dealer to have the heater inspected prior to further operation. • If the heater does not ignite the first time, do not try to ignite more than 2 more times in a row thereafter, as this could result in a fire. If the heater does not ignite after the third attempt, make no further attempts and consult your dealer prior to further operation of the heater. • When using the heater, be careful that the floor surface (in front of it) does not become overheated. Ignition POINT: To make sure the heater is ignited, do not leave the heater until you confirm that it is burning and otherwise functioning properly. 1. Turn the operating switch “ON”. The operating lamp will light and the heater will ignite in about 15 seconds. If ignition fails, try again as follows Stop operation completely. Wait for the operating lamp to turn off. After the operating lamp has turned off, attempt ignition again. DO NOT TRY TO IGNITE THE HEATER MORE THAN 3 TIMES IN A ROW AS FIRE MAY RESULT. Shut Off After operation has stopped, make sure that the flame is completely extinguished before leaving the heater unattended or moving or storing it. POINT: • Before you disconnect the power plug from the AC outlet, make sure that the combustion fan is stopped. • Never disconnect the power plug while the heater is operating as this will cause unexpected problem such as burn injury.
  • Page 67: Connecting The Control Device (Thermostat)

    Operation Connecting the Control Device (Thermostat) Terminals (A) 1. Uncouple the terminals (A) attached to the tips of the white wires coming out of the right side of the burner cover. 2. Connect both the male and female terminals, which are uncoupled, to the connectors (B) of the control device. Connectors (B) To Control Device • If the heater is controlled by another device (such as a thermostat or a timer), the heater could turn itself on at any time. • When the heater is controlled by another device, extra care must be taken to ensure that the heater is not accidentally turned on without someone nearby who can immediately attend to any problems when the heater is ignited, operating, and cooling off.
  • Page 68: Filter Cleaning

    Maintenance • Before starting any inspection or service, to avoid electrical shock, please make sure the heater is shut down and that the power cord is disconnected. • When cleaning the heater, please wear gloves to prevent possible injury. • Do not use a pressure washer for cleaning the heater. 1. All gas supplies must be closed before maintenance. 2. Before using, the heater must be cleaned using compressed air, a soft cloth or brush. 3. Be sure to check all gas connections with a soap and water solution. Filter Cleaning • Be sure to attach the filter prior to operation. Failure to do so will cause the burner to get clogged, causing unit to operate improperly. • When replacing the filter, use a genuine filter made by Shizuoka Seiki Co., Ltd. 1. Remove the cover by pulling out the filter case, and remove the filter. 2. Clean the removed filter or replace with a new filter. Please clean once a month. POINT: Use a brush with water, or use a vacuum cleaner to clean. Burner Head Cleaning When a misfire is detected while using in the environment with a lot of dust and welding fumes or when the heater is used after storing for an extended period of time, clean the burner head. 1. Remove the burner cover.
  • Page 69: Storage

    Storage If the heater is stored or not used for an extended period of time, shut off the main valve for propane gas and disconnect the gas hose. When storing the heater, please disconnect the power plug from the extension cord and/or the AC outlet and store the heater indoors where it is less humid. Trouble Recovery POINT: In case of problems with your heater, please refer to this checklist before consulting with your dealer. Please contact your dealer if results are not satisfactory even after referring to the table, or you have problems not described in this table. When consulting with your dealer, please describe the problem you have, also mentioning the model name and serial number of your heater. (To find the heater’s serial number, please refer to page 2.) Phenomenon Possible Cause Remedy Power cord is not connected with an Please connect the power cord with an The heater does not start. AC outlet. Power supply is cut off. AC outlet, and check the power supply. (The lamp does not light up.) Blown fuse Replace fuse with a new one. Please check all gas connections and The heater does not ignite. No gas supply. confirm that valves have been opened. The flame goes out during Check if there is any fuel in the cylinder No gas supply.
  • Page 71: Warranty Policy

    VAL6 Series Heaters by SHIZUOKA SEIKI WARRANTY POLICY VAL6 Infrared Heater series SHIZUOKA SEIKI warrants that its heaters and component parts will be free from defects in material and workmanship for a period of 24 months from date of purchase, when properly installed, operated, and maintained in accordance with the installation and Maintenance Instructions, safety guides and labels contained with each unit. If any component proves defective in either material or workmanship during the limited warranty period, Shizuoka Seiki, at its option, repair the defective part or equipment, or replace it with a new part or...
  • Page 72 USER REGISTRATION Please enter the following temporary ID & Password and complete the user registration form on our website. By completing your registration, you will obtain your own ID & Password. This allows you to download the owner’s manual and/or parts list from our website. • ID: VAL6 • Password: shizuoka • https://www.shizuoka-seiki.co.jp/english/ Manufacturer 4-1 Yamana-cho, Fukuroi 437-8601 Japan Tel +81-538-23-3990 Fax +81-538-23-3192 Printed in Japan 51003-200001A 1905-ATC...