The ventilation openings in the
housing floor must not be ob­
structed by carpeting.
Operating temperature of the
appliance is 5 to 35 °C.
Warning
Danger of suffocation!
No gas­fired heating systems
or gas­fuelled continuous­flow
water heaters, no coal stoves
with chimney connection and no
open fires may be operated at
the place of installation. Oth­
erwise, this may lead to under­
pressure and the suck­back of
exhaust gases.
The connection of the exhaust
air duct to chimneys to which
gas, coal­fired ovens or stoves
or gas­fired room heating
systems are connected is not
permitted.
40 EN

Installing the appliance

Notice
Do not install the dryer in an enclosed
area or in any area without fresh air
circulation.
The dryer works in accordance with
the exhaust­air principle. The moist
warm air generated during the drying
of the laundry exits through exhaust air
openings.
Route the exhaust air via an exhaust
duct to a ventilation shaft or into the
atmosphere (see
exhaust
duct)
If the supply of fresh cooling air is
inadequate, the dryer will suck in again
the warm and humid exhaust air.
This lengthens the time taken for
drying thus increasing the energy
consumption.
Install the dryer in a well ventilated
area to ensure that no gases from ap­
pliances that burn other fuels (includ­
ing open fire) flow back into the room
while the dryer is operating.
During the drying process take care to
ensure that the room is well ventilated
(open windows or the door, unclosable
ventilation openings in the walls or
doors).