234702_Gartenhacke.book Seite 29 Freitag, 1. Dezember 2017 8:37 08
Error/Fault
The motor does not work.

Technical data

Part number
Nominal voltage
Capacity
Protection class
Protection rating
Idle revolution
Working depth
Working width
Sound power level
(L
)*
WA
Sound pressure level
(L
)*
PA
Vibration
Weight
*) The specified values are emission values and do not
necessarily represent safe workplace values. Although
there is a correlation between emission and immission
levels, this cannot be used to infer whether additional
safety measures are necessary or not. Factors which
affect the current immission levels at the workplace,
include the type of room, other sources of noise, e. g. the
number of products being operated and other processes
taking place in the vicinity. Permitted workplace values
can differ from country to country. This information is
designed to help the user to better assess the dangers
and risks.
Cause
No power supply?
Defective connecting cable?
234702
230 V ~ /50 Hz
1400 W
II
IPX4
-1
330 min
20 cm
30,5-43 cm
93 dB (A)
79.2 dB (A)
< 1.5 m/s²
13.5 kg
GB
Remedy
Check the cable, plug, and the fu-
se.
Contact your dealer.