Jotul F118 Manuel D'installation page 11

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 15
Installation manual with technical data
1.0
Relationship to the authorities ...................11
2.0
Technical data ...............................................11
3.0
Installation .................................................. 12
4.0
Service .......................................................... 13
5.0
Optional Equipment ................................... 14
6.0
Information ................................................ 14
Figures/Pictures ................................................... 35
General use and maintenance manual
6.0
Safety precautions
7.0
Choice of fuel
8.0
Use
9.0
Maintenance
10.0
Operational problems - troubleshooting
On all our products there is a label
Product:
Jøtul
indicating the serial number and year.
Room heater fired by solid fuel
Write this number in the place indicated
Standard
:
Minimum distance to adjacent combustible materials:
Minimum distance to adjacent combustible materials:
in the installation instructions.
Emission of CO in combustion products
:
Flue gas temperature
:
Nominal heat output
:
Efficiency
:
Operation range
:
Fuel type
:
Always quote this serial number when
Operational type
:
The appliance can be used in a shared flue.
contacting your retailer or Jøtul.
Country
Classification
Certificate/
Approved by
standard
Norway
Klasse II
SP Sveriges Provnings- och
Sweden
SP
OGC
Forskningsinstitut AB
SP Swedish National
Testing and Research
EN
EUR
Intermittent
Institute
Follow user`s instructions. Use only recommended fuels.
Montage- und Bedienungsanleitung beachten.
Verwenden Sie nur empfohlenen Brennstoffen.
Respectez les consignes d'utilisation. Utilisez uniquement
les combustibles recommandés.
Serial no.
Serial no: Y-xxxx, Year: 200x
Manufacturer:
221546
Jøtul AS
POB 1441
N-1602 Fredrikstad
Norway
1.0 Relationship to the authorities
Installation of a fireplace must be according to local codes and
regulations in each country. All local regulations, including those
that refer to national and European standards, shall be complied
with when installing the product.
Instructions for mounting, installation and use are enclosed with
the product. Prior to using the product the installation must be
approved by a qualified person.
A product data plate in heat resistant material is located on the
heat shield under the product. This contains information about
identification and documentation for the product.
2.0 Technical data
Material:
Finish:
Fuel:
Log length, max.:
Flue outlet:
Flue pipe dimension:
cross section
Flue pipe adapter Ø150:
section
Approx. weight:
Optional extras:
Product dimensions, distances: See fig. 1
Technical data according to EN 13240
Nominal heat output:
Flue gas mass flow:
Recommended chimney draught: 13 Pa
Efficiency:
CO emission (13% O
):
2
Flue gas temperature:
Operational type:
Intermittent combustion in this context means normal use of the
fireplace, i.e. fuel is added as soon as the fuel has burnt down to
a suitable amount of embers.
Wood consumption
Jøtul F 118 has a nominal heat output of 7,0 kW. Use of wood,
with nominal heat emission: Approx. 2,5 kg/h. The size of the
logs should be:
Kindling:
Length: 20-40 cm
Diameter: 2-3 cm
Amount per fire: 8-10 pieces
Firewood (split logs):
Recomended length: 30 cm
Diameter: Approx. 8 cm
Intervals for adding wood: Approx. every 48 minutes
Size of the fire: 2,0 kg
Amount per load: 2-3 pieces
Nominal heat emission is achieved when the air vent ca. 75%
open and the rear air vent is closed.
ENGlish
Cast iron
Black paint
Wood
60 cm
Top, rear and side
Ø125 mm/123 cm
2
Ø150 mm/177 cm
cross
2
145 kg
Heat shields
7,0 kW
8,4 g/sec
73% @ 8,0 kW
0.23%
301
C
o
Intermittent
11

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

F 118

Table des Matières