Error Log - Gree Versati III Mode D'emploi

Masquer les pouces Voir aussi pour Versati III:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Operation Instructions for Versati III
27
AC current protection (input side)
28
IPM defective
29
PFC defective
30
Start failure
31
Phase loss
32
Communication error with the drive board
33
Driver resetting
34
Compressor overcurrent
35
Overspeed
36
Current sensing circuit error or current sensor error
37
Desynchronization
38
Compressor stalling
39
Radiator or IPM or PFC over-temperature
40
Radiator or IPM or PFC temperature sensor error
41
Charging circuit error
42
AC input voltage error
43
Ambient temperature sensor error at the drive board
44
AC contactor protection or input over-zero error
45
Temperature drift protection
Sensor connection protection ( the current sensor fails
46
to be connected with the corresponding phase U and or
phase V)
Communication error between the display panel and the
47
outdoor unit
48
Refrigerant vapor line temperature sensor error
49
Refrigerant liquid line temperature sensor error

2.5.4 Error Log

[Operation Instructions]
At the "VIEW" page, by touching "Error log", the control panel will go to the error log page, where it is able to
view error records.
[Notes]:
● The error log can accommodate up to 20 pieces of error. Name and occurrence time are available for each
error.
● When error log exceeds 20, the latest will supersede the earliest.
AC curr. pro.
IPM defective
PFC defective
Start failure
Phase loss
Driver Com.
Driver reset
Com. over-cur.
Overspeed
Current sen.
Desynchronize
Comp. stalling
Overtemp.-mod.
T-mod. sensor
Charge circuit
AC voltage
Temp-driver
AC contactor
Temp. drift
Sensor con.
ODU Com.
Temp RGL
Temp RLL
27
PA
H5
Hc
Lc
Ld
P6
P0
P5
LF
Pc
H7
LE
P8
P7
Pu
PP
PF
P9
PE
Pd
E6
F0
F1

Hide quick links: