Choose one of the following built-in configurations.
Installation allowed only with non combustible back
wall
Option 1: A >= 12'' (305 mm) and B >= 28'' (711 mm)
Option 2: A >= 28'' (711 mm) and B >= 12'' (305 mm)
* Clearances from non-combustible materials are not
part of the ANSI Z21.1 scope and are not certified by
"Intertek". Clearances of less than 3'' (76 mm) should be
approved by the local codes and/or by the local authority
having jurisdiction.
Island Installation (applicable both with non
combustible back wall and combustible back wall)
Option 1: A >= 12'' (305 mm) and B >= 28'' (711 mm)
Option 2: A >= 28'' (711 mm) and B >= 12'' (305 mm)
* purchased separately
** Clearances from non-combustible materials are not
part of the ANSI Z21.1 scope and are not certified by
"Intertek". Clearances of less than 3'' (76 mm) should be
approved by the local codes and/or by the local authority
having jurisdiction.
10
Low Backguard Installation (applicable both with non
combustible back wall and combustible back wall)
Option 1: A >= 12'' (305 mm) and B >= 28'' (711 mm)
Option 2: A >= 28'' (711 mm) and B >= 12'' (305 mm)
* purchased separately
** Clearances from non-combustible materials are not
part of the ANSI Z21.1 scope and are not certified by
"Intertek". Clearances of less than 3'' (76 mm) should be
approved by the local codes and/or by the local authority
having jurisdiction.

Technical Data

30" (5 burners):
Total connected load, electric
Total connected load, gas
(natural gas)
Total connected load, gas
(propane gas)
36" (6 burners):
Total connected load, electric
Total connected load, gas
(natural gas)
Total connected load, gas
(propane gas)
Oven:
Bake burner
Total connected load gas (nat-
ural gas/propane gas)
Broiler, 30" range
Total connected load gas (nat-
ural gas/propane gas)
Broiler, 36" range
Total connected load gas (nat-
ural gas/propane gas)
1 A (120 W)
48,000 BTU/h
(14.1 kW)
48,000 BTU/h
(14.1 kW)
1 A (120 W)
63,000 BTU/h
(18.4 kW)
63,000 BTU/h
(18.4 kW)
17,000 BTU/h
(5.0 kW)
11,500 BTU/h
(3.4 kW)
14,000 BTU/h
(4.1 kW)