Technical Characteristics - tau K122M Notice D'installation

Masquer les pouces Voir aussi pour K122M:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

LOGICS WITH MICROPROCESSOR
STATUS OF INPUTS SIGNALLED BY LEDs
"PEDESTRIAN GATE" FUNCTION
INCORPORATED FLASHING CIRCUIT
ENCODER SENSOR FOR OBSTACLE DETECTION AND SELF-LEARNING OF TRAVEL
RECEIVER CONNECTOR
BATTERY AND BATTERY CHARGER CONNECTOR (OPTIONAL)
DIAGNOSTICS OF MALFUNCTIONS SIGNALLED BY LED
When you have completed the connection:
 All the green LS LEDs must be on (each of them corresponds to a Normally Closed input).
The go off only when the controls to which they are associated are operated.
 All the red LS LEDs must be off (each of them corresponds to a Normally Open input). The
light up only when the controls to which they are associated are operated.
Before proceeding, make sure the mechanical components work correctly. Also check
that the gear motor assembly has been installed according to the instructions. Then make
sure that the power consumption of the gear motor is not greater than 3A (otherwise the
control panel may not work properly).
THE EQUIPMENT MUST BE INSTALLED "EXPERTLY" BY QUALIFIED PERSONNEL AS
REQUIRED BY LAW.
NB : it is compulsory to earth the system and to observe the safety regulations that are
in force in each country.
IF THESE ABOVE INSTRUCTIONS ARE NOT FOLLOWED IT COULD PREJUDICE
THE PROPER WORKING ORDER OF THE EQUIPMENT AND CREATE HAZARDOUS
SITUATIONS FOR PEOPLE. FOR THIS REASON THE "MANUFACTURER" DECLINES ALL
RESPONSIBILITY FOR ANY MALFUNCTIONING AND DAMAGES THUS RESULTING.
ATTENTION:
-
do not use single cables (with one single wire), ex. telephone cables, in order to avoid
breakdowns of the line and false contacts;
-
do not re-use old pre-existing cables;
-
we recommend to use the TAU cable code M-03000010C0 to connect the motors to the
control board.
Board power supply
Max motor power DC
Fast acting fuse for protection of input power supply 13.5 Vac (F1 - 5x20)
Fast acting fuse for motor protection (F2 - 5x20)
Fast acting fuse for protection of auxiliary circuits 18 V dc (F3 - 5x20)
Motor power supply circuits voltage
Auxiliary device circuits supply voltage
Logic circuits supply voltages
Operating temperature
14
CONTROL BOARD FOR SPEED 2 GEARMOTOR

TECHNICAL CHARACTERISTICS

K122M
English
TESTING
INSTALLATION
13,5 Vac - 50 Hz
50 W - 18 Vdc
F 16A
F 10A
F 1,6A
18 Vdc
18 Vdc
5 Vdc
-20 °C ÷ +70 °C

Publicité

Table des Matières
loading

Table des Matières