DOOR PANEL INSTALLATION
L
amps wiring.
Once the nameplate labels are placed, wire the
lamps from different modules and connect them
to terminals L1 and L2 of the sound module.
If the number of door panel lamps is higher than eight,
connect a TF-104 transformer between ~1 and ~2
terminals of the sound module and change JP2 jumper
position.
NOTE: Don't change JP1 jumper position. JP1 and JP2 jumpers are placed
on the left side of the sound module terminal connector.
F
inal adjustments.
If after starting the system it's considered that the audio
volume isn't correct, proceed with the necessary
adjustments as shown.
The telecamera has a pan and tilt mechanism built in
to adjust the telecamera position.
In case of low light conditions, an external illumination
can be activated by connecting a R-3 relay
between terminals '+H' and 'L2' of the sound module.
C
lose the door panel.
Fix the door panel by using the supplied
screws.
Finish the door panel assembly by pressing
the closing heads.
85
86
I
nstalling the FA-PLUS and FA-PLUS/C power supplies.
3,5 x 25
DIN-7971
The power supply can be installed on a DIN 46277 guide
simply pressing it. To disassemble the power supply
from the DIN guide, use a plain screwdriver to lever
the flange as shown on the picture.
The FA-Plus/C model uses 6 units over DIN guide
and 10 units the FA-Plus model.
IMPORTANT: the maximum number of units that can be connected to a FA-Plus/C power
supply is 10, and 50 units in case of a FA-Plus model.
Link power supplies to connect more units than the specified as it's shown
on page 96.
L
ock release installation.
If the lock release will be installed in a metal door, use a
Ø3,5mm. drill and tap the hole . In case of wood door,
use a Ø3mm. drill .
IMPORTANT: the lock release to be used must be of 12Vd.c.

POWER SUPPLY INSTALLATION

The power supply must be installed in a dry and
3,5 x 25
protected place. It's recommended to protect
DIN-7971
the power supply by using a thermo-magnetic
circuit breaker and to use a ground connection.
To install the power supply directly on the wall, drill two holes
of Ø6 mm. and insert the wallplugs.
Fix the transformer with the specified screws.
DIN 46277

LOCK RELEASE INSTALLATION

If you are using a.c. lock releases, use one R-3 relay unit and
one TF-104 transformer to activate it, as it is shown on page 96.
3,5 x 25
DIN-7972
M 4 x 8