Installation Diagrams - golmar Stadio Plus Manuel D'installation

Masquer les pouces Voir aussi pour Stadio Plus:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

TELEPHONES PROGRAMMING
P
rogramming the telephones.
Set to ON the switch number 2 of the configuration dip switch, that's
accessible by opening the terminal connector protection cover.
The door panel will reproduce a sound to advise that the system
has entered into programming mode.
In systems with more than one door panel, the programming process
shall be done on the master door panel only.
Switch off the telephone to be programmed.
Once the telephone is off, press the door release push button.
With the door release push button pressed
switch on the telephone.
To show that the system is ready for programming,
the door panel will reproduce a sound and
the telephone led will blink. At this moment, the door
release push button can be released. Lift the handset
to establish audio communication with the door panel.
Each apartment must have one master unit only; in case of parallel units configure them
as slaves, both monitors or telephones.
Make a call to check that the telephone has been succesfully programmed.
Repeat these steps to program the rest of telephones.
Once the programming has been finished, set to OFF the programming
switch. If you don't, the door panel will reproduce a sound to advise
that the system is still into programming mode.
95
Press the door panel push button that will
call to this telephone. At this moment
the door panel will reproduce a sound
and the telephone led will blink.
To program the telephone as master,
switch it off and on again.
To program it as slave, press the door
release push button.
To program it as slave with intercom
function press the center push button.
96
C
onnexion of an a.c. lock release.
As it is described on page 86, the lock releases to be connected to the door panel
must be d.c. type. If an a.c. lock release has been installed before, use a R-3
relay unit and a TF-104 transformer, and connect them to the lock release
as it is shown on the enclosed diagram.
TF-104
R-3
SEC
~
~
O
B
R
T
M
L
ink of several power supplies units.
If the quantity of monitors or telephones to be connected is bigger than the supported
from one power supply (see page 86), use additional power supplies to match the
required quantity. The first power supply should be connected to the door panel and
to the first group of monitors or telephones; connect the next groups to the positive
terminal of its corresponding power supply.
To wire several power supplies link their ground terminals;
NEVER link positive terminals of different power supplies.
1st FA-Plus
2nd FA-Plus/C or FA-Plus
PRI
SEC
PRI
~
~
-
-
~
~
+ +
Main
Main

INSTALLATION DIAGRAMS

Door panel
CN1
CV-
CV+
-
+
D
A
A
V
V
V
V
Malla
out
in
in-
in+
out+
out-
SEC
-
-
+ +
To the second group of
monitors or telephones.
To the door panel and to
the first group of monitors
or telephones.

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

T500mlStadio plus t500ml

Table des Matières