8 | Setup and installation
NOTICE
Material and property damage due to incor-
rect setup.
§ Place the appliance in a stable operating position
(horizontal alignment).
§ Only set the appliance down onto the feet when
the feet are completely assembled.
§ Do not expose the appliance to heat radiation at
the place of installation.
§ Do not expose the appliance to direct air condition-
ing or ventilation at the place of installation.
§ Do not install the appliance outdoors.
§ Pour approx. 1 litre of water into the rear defrost
water bowl before use.
Material and property damage due to accumu-
lation of warm exhaust air (heat accumula-
tion).
§ The exhaust air must escape freely at the top of
the appliance.
§ Superstructures or false ceilings directly on the up-
per edge of the appliance may only be installed in
consultation with the manufacturer.
§ A gap of at least 250 mm must be permitted
between the ceiling and any mounted marketing
placards in order that warm exhaust air can es-
cape.
§ Do not set down any objects on the appliance.
Do not cover the temperature display, safety notes, or
the rating plate [see } Chapter 3.2.1].
The minimum distance from the upper edge of the ap-
pliance to the ceiling is 600 mm.
The minimum distances to the boundary walls and to
other equipment are determined by the equipment feet
provided for this purpose.
1
2
Fig. 16: Wall installation of KINLEY (1) with refrigerator/
freezer (2) at bottom (front and side view)
1
1
2
2
Fig. 17: Island installation of KINLEY (1) with refrigerator/
freezer (2) at bottom (side view)
For hygiene reasons, do not stick any advertising films
or other materials onto the appliance.
52 / 788
Installing the display shelves and mesh
baskets
Responsibility
– Operating company
CAUTION
Incorrect installation of the display
shelves or mesh baskets.
Risk of injury due to falling of the display
shelves holding goods or the mesh baskets.
§ Display shelves or mesh baskets must
fully engage in the openings provided
when inserted.
§ Note installation of the display shelves or
mesh baskets [see } Chapter 8].
NOTICE
Material damage due to deformation of the
display shelves.
§ Align the display shelves horizontally.
§ Align the mesh baskets horizontally.
Installing the display shelf or mesh basket
a) Attach the display shelf or mesh basket to the
openings in the rear wall.
Fig. 18: Attach the display shelf or mesh basket

Communication interface

The appliance features a communication interface
(bus connection). This interface can be used to con-
nect the appliance to a monitoring system.
Several appliances can be interconnected via the
communication interface. Depending on the appliance
type and configuration, it may be necessary to inter-
connect several appliances.
NOTICE
Material and property damage due to faulty
communication between appliances and with
the monitoring system.
§ Never break an existing bus connection.
Appliances can be connected using bus cables (op-
tional accessories).
8.1

Electrical connection

The operator establishes the connection to the power
supply.
Technical data [see } Chapter 3.2]
AHT Cooling Systems GmbH | en
376840_1_0920