AHT Cooling Systems GmbH | en
Press
Deactivate key lock
simultaneously for 5 seconds.
(Level 1 access)
Level 1 is activated.
Assign bus address
– Switch off cooling function: Press
1.
for at least 1 second.
appears on the display.
– Immediately thereafter, briefly press
times in succession.
2.
appears on the display alternately with
the current bus address, e.g. .
– Assign the next highest bus address (indi-
vidual step):
Briefly press
3.
– Quick run through the bus addresses:
Hold
pressed.
– Use new entry:
Wait 5 seconds.
4.
appears on the display.
– Switch the cooling function back on:
Press for at least 1 second.
5.
The current interior temperature appears on
the display.
Assign bus addresses for further appliances:
e) Repeat points 1 to 5 on each appliance and select
an available bus address.
When the cooling function is switched off, the door
heating is automatically switched off as well.
f) After switching on the cooling function, the door
heating must therefore be switched on again sep-
arately.
5.3.6

Door heating

Optional
Press
Deactivate key lock
simultaneously for 5 seconds.
(Level 1 access)
Level 1 is activated.
Switch on door heat-
ing
Switch off door heat-
ing
5.3.7

Alarm

Display alarm
An error code appears on the display as a flashing in-
dication alternating with the internal temperature.
376840_1_0920
and
appears on the display.
.
and
appears on the display.
or
press briefly .
appears on the display.
or
press briefly .
goes out on the display.
The symbol
appears on the display.
As an option, it is possible to output an acoustic
alarm by means of a built-in buzzer.
Troubleshooting measures for the occurrence of alarm
indicators; see [see } Chapter 10.3].
Error code
3
Acknowledge alarm
Deactivate key lock
(Level 1 access)
Error code and Ac-
knowledge acoustic
alarm
(device-specific)
Call error code to
check
5.4

Electronic controller Carel

Keys are available as control elements, with the fol-
lowing assignments:
Control and display elements | 5
Meaning
Sensor error F1
Sensor error F2
Sensor error F4
Time/date error
Overtemperature alarm
Overtemperature at F4
Low temperature alarm
Temperature logger alarm
Electronic error
Electronic overtemperature
Compressor error
Compressor error due to E75
Voltage outside tolerance
Frequency outside tolerance
No communication with display
Electronics in test mode
Press
and
simultaneously for 5 seconds.
appears on the display.
Level 1 is activated.
press briefly .
The interior temperature and
the symbol
appear on the
display.
The symbol
is illuminated
until the error has been recti-
fied.
press briefly
The error code is shown on the
display for approx. 5 seconds.
The current interior temperature
is then shown again.
45 / 788