Jtroubleshooting; J.1 Alarms - Zanussi ZXLIG Instructions D'installation

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 55
J
TROUBLESHOOTING
J.1
Alarms
Alarm
Display message
number
01
TANK FILLING
02
BOILER HEATING
03
TANK HEATING
04
TANK DRAINING
05
BOILER FILLING
06
BOILER PROBE
07
TANK PROBE
08
Thermostop TIME-OUT
09
BOILER SAFETY SWITCH
10
TANK SAFETY SWITCH
12
PANEL CONNECTION
13
PARAMETER ERROR!
15
SERVICE WARNING
Type of anomaly
Tank NOT filling
Boiler NOT heating
Tank NOT heating
Inefficient drainage
Boiler NOT filling
Boiler probe temperature out-
side range
Tank probe temperature out-
side range
Thermostop time-out before
rinse
Boiler safety thermostat
intervention
Tank safety thermostat
intervention
No communication circuit board
The parameters have been
compromised
The number of cycles for main-
tenance reached
Actions
Open the tap.
Clean the water inlet filter.
Make sure drain pipe does not kink, pinch or
twist.
Check the minimum mains pressure.
Insert properly the overflow.
Rinse arm nozzles clogged.
CALL THE SERVICE CENTRE
CALL THE SERVICE CENTRE
Remove the overflow.
Make sure the pump filter is not clogged.
Remove any obstruction from the waste
outlet pipe and/or the overflow aperture.
Open the tap.
Clean the water inlet filter.
Make sure drain pipe does not kink, pinch or
twist.
Check the minimum mains pressure.
CALL THE SERVICE CENTRE
CALL THE SERVICE CENTRE
CALL THE SERVICE CENTRE
CALL THE SERVICE CENTRE
CALL THE SERVICE CENTRE
CALL THE SERVICE CENTRE
CALL THE SERVICE CENTRE
CALL THE SERVICE CENTRE
ENGLISH
19

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

406402315

Table des Matières