Typical Direct Mount Installation (to underground tank)
Materials:
2" pipe cut to length
and threaded at both
ends that will extend
approximately 31"
above the ground
when installed in the
tank flange.
1-1/4" pipe cut to a
length that will extend
to approximately 3" of
the bottom of the tank
when screwed into the
tank adapter with the
tank adapter screwed
into the pipe coupling
(see DIRECT
MOUNTING
INSTALLATION
diagram).
Threaded pipe joint
sealant appropriate for
application.
Installation Procedure:
1)
Install the 2" pipe in
the tank flange; seal
threads liquid tight
with appropriate
sealant.
2)
Screw a 2" standard
pipe coupling onto the
top of the pipe; seal
threads liquid tight
with appropriate
sealant.
3)
Screw the 1-1/4" pipe into the tank adapter. Seal threads liquid tight with appropriate
sealant.
4)
Screw the tank adapter into the 2" coupling; seal threads liquid tight with appropriate
sealant.
5)
Mount pump on tank adapter; seal threads liquid tight with appropriate sealant.
WARNING! Threaded pipe joints and connections should be sealed with the
appropriate sealant or sealant tape to minimize the possibility of leaks.
MAXIMUM LIFT
Gasoline 10' (3 m)
Diesel 12' (3.7 m)
5
Additional specifications on page 15.