Quick-Acting Pipe Welding Clamp Instructions
Quick-Acting Pipe Welding Clamp
Instructions
Read and understand these in-
structions and the warnings and
instructions for all equipment and
material being used before operat-
ing this tool to reduce the risk of
serious personal injury.
SAVE THESE INSTRUCTIONS!
• Use appropriate safety equipment. Always wear proper
eye and foot protection. Dust mask, face shield, hearing
protection or other equipment may be needed to reduce the
risk of injury.
• Do not use the Pipe Clamp for lifting, supporting or
transporting. It is not designed for these uses and could
allow the workpiece to fall and cause serious injury. Only
use as directed in these instructions.
• Properly support the workpieces. Use pipe stands,
tables, vises or other methods to support workpieces.
Failure to properly support the workpiece can allow it to fall
and cause serious injury.
If you have any question concerning this RIDGID
– Contact your local RIDGID distributor.
– Visit RIDGID.com to find your local RIDGID contact point.
– Contact Ridge Tool Technical Service Department at rtctech-
services@emerson.com, or in the U.S. and Canada call (800)
519-3456.
Description
RIDGID
Pipe Welding Clamps are used to align pipes/fittings
®
and other cylindrical workpieces for welding. It includes a quick
acting feature for fast installation and use. The wing bolts that
grip the pipe are made of stainless steel.
Handle
Grip
Jaws
Workpiece
Contact
Figure 1 – Quick-Acting Pipe Welding Clamp
Specifications
Model ...................QA-206
Catalog Number ...57258
Capacity ..............2" to 6"
50 to 150 mm
Weight .................11 lbs (5 kg)
Size ......................8.5" x 12.75" x 4.25"
(Closed)
(216 x 324 x 108 mm) (349 x 457 x 108 mm)
NOTICE
Use of equipment for both carbon and stainless steel
pipe can lead to contamination of the stainless steel material.
Printed 2/18
EC43395
The Emerson logo and RIDGID logo are registered trademarks of Emerson Electric Co. or RIDGID, Inc. in the U.S. and other countries.
WARNING
product:
®
Feed Screw
Release
Feed Screw
Wing
Bolt
QA-412
57263
4.5" to 12"
112 to 300 mm
16.7 lbs (7.6 kg)
13.75" x 18" x 4.25"
All other trademarks belong to their respective holders.
This contamination could cause corrosion and premature pipe
failure. To reduce the risk of ferrous contamination of stainless
steel pipe, use dedicated equipment. Alternately, a stainless steel
wire brush may be used to thoroughly clean the equipment when
switching between materials.
Inspection/Maintenance
Clean the pipe clamp to aid inspection and improve control.
Clean workpiece contact points with a wire brush to remove dirt.
Inspect before each use for proper assembly, wear, damage,
modification or other issues that could affect safe use. If any
problems are found, do not use until corrected.
Lubricate points of relative motion with a light weight general
purpose lubricating oil. Wipe off any excess oil.
Set Up/Operation
1. Make sure workpieces are secure and cannot fall.
2. Loosen the three wing bolts. The tip of the wing bolt should
not contact the workpiece when initially installed.
3. To open clamp, use one hand to hold the grip and press the
feed screw release
dle
2
and open the jaws. Stay clear of pinch points. (Fig-
ure 2).
2
1
OPEN
Figure 2 – Opening and Closing Clamp
4. Place the jaws around a
cylindrical end of the work-
piece with the wing bolts
oriented towards the end.
Push the handle to close
the jaws (Figure 2). The
three contact points should
sit squarely on the work-
piece surface. Tighten the
handle to secure the clamp
to the workpiece (Figure
3). Do not overtighten.
5. Tighten all the wing bolts
until the tips lightly con-
tact the workpiece sur-
face. Do not overtighten
(Figure 3 inset).
6. Loosen the handle (ap-
proximately 1 turn) and
slide the pipe clamp so
the wing bolts extend approximately 2" (50 mm) from the
end of the workpiece (Figure 4). Tighten the handle and
secure the clamp to the workpiece. Do not overtighten. Do
not use handle extensions - the tool can be damaged.
7. Loosen one wing bolt (typically the upper wing bolt)
2-3 turns. Align the second workpiece with the first and
place between the wing bolt tips, setting the desired gap
between the workpieces. Tighten the loosened wing bolt.
©2018 RIDGID, Inc.
1
. Use the other hand to pull the han-
CLOSE
Figure 3 – Clamp On Workpiece
999-998-445.10
REV. A

Publicité

loading

Sommaire des Matières pour RIDGID QA-206

  • Page 1 999-998-445.10 ©2018 RIDGID, Inc. Printed 2/18 EC43395 The Emerson logo and RIDGID logo are registered trademarks of Emerson Electric Co. or RIDGID, Inc. in the U.S. and other countries. REV. A All other trademarks belong to their respective holders.
  • Page 2 2. Desserrez les trois vis papillon. Aucune des pointes de vis queraient de tomber et provoquer de graves blessures. papillon ne doit entrer en contact avec le tuyau lors de son En cas de questions visant ce produit RIDGID , veuillez : ®...
  • Page 3 1 tour, puis faites Figure 3 – Pince posée sur tuyau – Comuníquese con el distribuidor RIDGID en su localidad. glisser la pince en avant jusqu’à ce que les vis papillon – Visite RIDGID.com para averiguar dónde se encuentra el dépassent l’extrémité...
  • Page 4 Quick-Acting Pipe Welding Clamp Instructions Especificaciones 6. Afloje la manija (aproxi- madamente una vuelta) y Modelo ....QA-206 QA-412 deslice la abrazadera hasta No. de catálogo ..57258 57263 que los pernos de orejas Diámetro ....2" a 6" 4,5" a 12" sobresalgan unas 2 pulga-...

Ce manuel est également adapté pour:

Qa-412