Environmental Protection - Xylem JABSCO NEMP 40/4 Mode D'emploi

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 12

6. ENVIRONMENTAL PROTECTION

GB
Due consideration to environmental issues
within the design and manufacturing process
of this product without compromising product
performance and value.
WEEE Policy
The Waste Electrical and Electronic Equipment
Directive (WEEE Directive) is a European Community
directive 2002/96/EC on waste electrical and
electronic equipment (WEEE) Directive 2002/95/EC
which became European Law in February 2003. The
WEEE Directive set collection, recycling and recovery
targets for all types of electrical goods.
Xylem Water Services Limited has identified that
there product range comes under Category 6
(Electrical tools) and as such will undertake their
responsibilities in line with the above directive and
will fulfil their legal obligation by means of joining a
compliance scheme.
All products are identified by means of the
Wheelie bin logo as laid down in the above
directive.
The Xylem Water Services Limited WEEE producer
registration number is WEEE/RM07081
Full details of scheme can be found at:
Valpak Limited
Unit 4, Montague House
Stratford-upon-Avon Business and Technology Park
Banbury Road
Stratford-upon-Avon
Warwickshire
CV37 7GW
UK
At the end of your product and accessories life, it
must not be discarded as domestic waste.
Please contact your distributor / supplier for further
information. For end users outside of the EU consults
applicable regulations.
This product should only be dismantled for recycling
by an authorized recycling company.
7. PRODUCT OPERATION OPERATING
CONDITIONS
• All pump models are rated for the following
temperature range of the pumped fluid -20°C /
-4°F to 85°C / 185°F
• Ensure there are no leaks or blockages in system.
• Clear air from pump on initial start-up cycle, turn
unit on / off for five second intervals to clear air
from pump.
• DO NOT RUN PUMP DRY
• Install sea strainer to prevent particles and debris
from entering pump
• PUMP DOES NOT SELF-PRIME
• Pump must be mounted below waterline.
Storage and Cleaning
• If any pump unit needs to be removed for storage
purposes, it must be stored in a cool dry location.
• Pump units have been designed to meet IP55
standards are not permitted to be cleaned using a
pressure washer. It is recommended that the unit
is wiped down after use to remove excess residue,
dirt or dust.
• These magnetically coupled pumps are designed
for use with clean fluids.
• Solids will cause jamming. Abrasives will reduce
pump life & invalidate the warranty.