Parameter list
Param-
Level
Description
eter
H y
Pr1
Switching hysteresis
L S
Pr2
Bottom target value
limit for set
U S
Pr2
Top target value limit
for set
o t
Pr1
Calibration of target
value sensor
P 2 P
Pr1
Operation with evapo-
rator sensor
o E
Pr2
Evaporator sensor
calibration
o d S
Pr2
Relay delay when
"ON"
db
Pr2
Neutral zone control
(loading area tempera-
ture control)
AC
Pr1
Relay power-off dura-
tion
C C t
Pr2
Continuous operation
of compressor
C C S
Pr2
Target value for
shock freezing
C o n
Pr2
Switch-on time for
sensor - error
C O F
Pr2
Switch-off time for
sensor - error
C F
Pr2
Units of measurement
celcius / fahrenheit
r E S
Pr1
Display with decimal
point
Ld 1
Pr2
Top display
Ld 2
Pr2
Bottom display
d L y
Pr2
Temperature display
delay
t d F
Pr1
Defrosting mode
Area
Deep
freez-
ing with
hot gas
defrosting
(0.1 °C ÷ 25.5 °C)
2
(1 °F ÷ 45 °F)
(– 55 °C ÷ SEt)
– 20
(– 67 °F ÷ SEt)
(SEt ÷ 150 °C)
40
(SEt ÷ 302 °F)
(–12 °C ÷ 12 °C)
–1
(– 21 °F ÷ 21 °F)
(n = no) (y = yes)
y
(–12 °C ÷ 12 °C)
–1
(– 21 °F ÷ 21 °F)
0 ÷ 255 (min)
0
(n = no) (y = yes)
n
0 ÷ 50 (min)
0
0.0 ÷ 24 (hrs)
0
(– 55.0 °C ÷ 150 °C)
0
(– 67 °F ÷ 302 °F)
0 ÷ 255 (min)
0
0 ÷ 255 (min)
0
°C / °F
°C
(in = without)
in
(dE = with)
P1 / P2 / P3 / P4 /
P1
SET / dt
P1 / P2 / P3 / P4 /
SET
SET / dt
0 ÷ 20 (MO) (120)
0
(10 sec)
(EL = circulation)
in
(in = hot gas)
Frigo
Chilled goods
with loading
area tempera-
ture control
2
2
12
–1
y
–1
0
y
0
0
0
0
0
°C
in
P1
SET
0
in
29