GAS CONNECTIONS
NOTE: To ensure proper heating performance of this appliance, verify that the supply (inlet)
NOTE:
pressure is adequate (11-14 inch WC [2.74-3.48 kPa] pressure is preferred) to maintain 10 inch WC
[2.49 kPa] nominal outlet (manifold) pressure.
EN
LP TANK RESTRAINT
Be sure to restrain the LP cylinder by securing it with the retention eyebolt as shown below. It is
important the tank does not fall over or stretch the hose which could cause a gas leak. Take care to
point the regulator & hose to the right of the drawer as shown in the image on pg. 13. This is necessary
to avoid kinking or otherwise damaging the hose when pushing the drawer back in.
LP TANK
RESTRAINT

LEAK TESTING

GENERAL
Although all gas connections on your Hestan grill are leak tested at the factory prior to shipment, a
complete gas tightness check must be performed at the installation site due to possible movement
in shipment, or excessive pressure unknowingly being applied to parts of the unit. Periodically
check the whole system for leaks, or immediately check if the smell of gas is detected.
BEFORE TESTING
BEFORE TESTING
Do not smoke while leak testing.
Never leak test with an open flame.
Make a soap solution of one part liquid detergent and one part water for leak testing purposes.
Apply the solution to the gas fittings by using a spray bottle or a brush.
For LP units, always check with a full LP cylinder.