Fitting Appliance Cover Over Water Installation On; Finished Walls; Lower Back Panel Section Installation With Threaded Fittings On Finished Walls; Wall Mounting Bracket When Replacing Appliance - Stiebel Eltron DHB-E 11/13 LCD Utilisation Et Installation

Masquer les pouces Voir aussi pour DHB-E 11/13 LCD:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 45
INSTALLATION
Alternative installation methods
13.7 Fitting appliance cover over water installation
on finished walls
4
3
2
1
1 Back panel guides
2 Screw
3 Cover guides with sealing lips on the pipe side
4 Pipe knock-out
f Cleanly saw and break out the pipe knock-outs in the appli-
f
ance cover. If necessary, use a file.
f Click the cover guides into place in the knock-outs.
f
Only if using the "solder fitting" accessory and with precise
adherence to all installation dimensions:
f Break the sealing lips out of the cover guides.
f
f Position the back panel guides on the pipes. Push them to-
f
gether. Then push the guide pieces against the back panel as
far they will go.
f Secure the lower back panel section with a screw.
f
Note
You can use the cover guides with sealing lips to com-
pensate for a slight offset of the connection pipes and/
or if using the "press fitting" accessory. In this case, the
back panel guides are not fitted.
13.8 Lower back panel section installation with
threaded fittings on finished walls
3
1
1 Lower back panel section
2 Connection piece in the standard delivery
3 Screw
If using threaded fittings on finished walls, the lower back panel
section can also be installed after fitting the taps/valves. To do
this, carry out the following steps:
f Cut open the lower section of the back panel.
f
f Fit the lower section of the back panel by bending it out at
f
the sides and guiding it over the pipes.
f Insert the connection pieces into the lower section of the
f
back panel from behind.
38
| DHB-E LCD
f Click the lower section of the back panel into place.
f
f Secure the lower back panel section with a screw.
f
13.9 Wall mounting bracket when replacing
An existing STIEBEL ELTRON wall mounting bracket may be used
when replacing appliances (except for DHF instantaneous water
heater), as long as the fixing screw is in the lower right position.
Replacing a DHF instantaneous water heater
f Reposition the fixing screw on the wall mounting bracket (the
f
securing screw has a self-tapping thread).
f Rotate the wall mounting bracket 180° and mount it on the
f
wall (the DHF logo is then turned towards the reader).

13.10 Installation with offset tiles

1 Minimum contact area of the appliance
2 Maximum tile offset
f Adjust the wall clearance. Lock the back panel in place using
f
the fixing toggle (turn 90° clockwise).

13.11 Pivoting appliance cover

The appliance cover should be turned round for undersink in-
2
stallation.
f Remove the programming unit from the appliance cover by
f
pressing the locking hooks and removing the programming
unit.
appliance
20
2
1
www.stiebel-eltron.com

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Dhb-e 18 lcd 25aDhb-e 18/21/24 lcdDhb-e 27 lcd