Commissioning; Preparation; Initial Start-Up - Stiebel Eltron DHB-E 11/13 LCD Utilisation Et Installation

Masquer les pouces Voir aussi pour DHB-E 11/13 LCD:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 45
INSTALLATION

Commissioning

11. Commissioning

11.1 Preparation

Internal anti-scalding protection via jumper slot
Jumper position
Description
43
For example, nurseries, hospitals etc.
50
55
Max. for shower operation
60
Factory setting
No jumper
Limited to 43 °C
f Install the anti-scalding protection setting jumper in the re-
f
quired position (= temperature in °C) on the pin strip.
CAUTION Burns
If operating with preheated water, e.g. if using a solar
thermal system, the internal anti-scalding protection can
be overridden.
f In this case, limit the temperature with an upstream
f
central thermostatic valve (e.g. ZTA 3/4).
Changing the connected load via the jumper slot; only for
appliances with adjustable output
If you select a connected load other than the factory setting for
appliances with selectable connected load, you will need to repo-
sition the jumper.
f Install the jumper in the required position on the pin strip.
f
Jumper position
Connected load
DHB-E 11/13 LCD
1
11 kW
2
13,5 kW
3
11 kW
No jumper
11 kW
www.stiebel-eltron.com
43
50
55
60
1
2
3
Connected load
DHB-E 18/21/24 LCD
18 kW
21 kW
24 kW
18 kW

11.2 Initial start-up

f Open and close all connected draw-off valves several times,
f
until all air has been purged from the pipework and the
appliance.
f Carry out a tightness check.
f
f Activate the safety switch by firmly pressing the reset button
f
(the appliance is delivered with the safety switch disabled).
f Connect the programming unit connecting cable to the PCB.
f
Note
For undersink installation, the appliance cover should
be turned round for easier operation; see chapter "Alter-
native installation methods / Pivoting appliance cover".
f Hook the appliance cover at the top rear into the back panel.
f
Pivot the appliance cover downwards. Check that the appli-
ance cover is securely seated at both top and bottom.
f Tick the selected connected load and rated voltage on the ap-
f
pliance cover type plate (on both sides). Use a ballpoint pen
to do this.
f Secure the appliance cover with the screw.
f
f Fit the fascia to the appliance cover.
f
f Remove the protective film from the user interface.
f
f Switch on the power supply.
f
≥ 60 s
DHB-E LCD |
35

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Dhb-e 18 lcd 25aDhb-e 18/21/24 lcdDhb-e 27 lcd

Table des Matières