General warnings and remarks
Use qualified electrician for electric installations!
The device shall be connected to grounded outlet with RCD protection.
The electric parts of the product are splash water protected (IPX4).
The device should be installed as close to the pool as possible according to national and local regulations
and if possible to the same level as the pool floor.
Make sure that water can flow away from the installation place to prevent flooding. Consider rain fall
and also overflow from the hot tub.
The installation location has to be flat and able to support the product installation.
If the device is used during winter it has to be protected from snow fall.
The device must be easily accessible for maintenance.
The device must be installed into a location where it can be supervised so that children do not play
around or with the device.
Do not plug in / turn on the device when the pool is empty or the water flow has been blocked.
If the tub is going to be emptied for winter. You must move the device to warm storage or
empty it totally from water with compressed air or water vacuum cleaner. So that there will
not be any water left in the pipes, heater element or the pump that would freeze and break
the system.

Electric installation

Since the product is in the scope of standard EN 60335-2-60:2003. It must be
fixed or half fixed installed to electric supply. The installation shall be carried
out by a person with local permissions and qualifications.
The device must always be connected after a RCD breaker.
The device full power is ca. 2,3kW / 3,3kW.
The connection shall be made with rubber cable that is designed for
outdoor use and has wires at least 3 x 1,5 mm
2
2,5 mm
for 3kW version
The device has ready made holes and strain relief, use those to lead
the cable into the electric box.
On the right a connection drawing for electrics.
Tubtainer 2 heater/filter system
TECHNIAL INFORMATION
Power supply
Heating power
Pump power
Filtration area
Flow rate
Fuse size
Max pressure
Measures (L x W x H)
Dry weight
IP class
INSTALLATION
22.12.2020
39/108
230V~, 50Hz
2 kW
250 W
2,3 m2
4,4 m3/h
Min 10A / 2 kW
16A / 3 kW
3,45bar (50 PSI)
635 x 410 x 695 mm
31 kg
IP X4
2
for 2kW version and 3 x
P
3/17