D
WALT AirLock System
E
DWV9000
Twist-Lock
connection
DWV9110
29-35 mm tapered
rubber adapter
DWV9120
35-38 mm stepped
rubber adapter
DWV9130
35 mm OD adapter
DWV9150
35 mm OD angle
adapter
VAC RACK DWV9500 INSTALLATION (FIG. 10)
NOTE: The DWV901LT comes with DWV9500 vac
rack attachment already installed,
1. Remove the 4 carry handle screws using a T-25
star bit and remove the carry handle.
2. Install the vac rack reusing the carry handle
screws. Put them back in their original holes
and tighten.
3. Use the 2 screws (v) provided by placing
them in the rear holes of the vac rack. Push
down and turn each screw to break through
the material and into the hidden screw boss
below. Tighten.
CAUTION: Do not exceed 9 kg (20 lb)
in each 14 liter storage unit, maximum
2 storage units per dust extractor. Do
not exceed 18 kg (40 lb) in a 28 liter
storage unit, 1 storage unit per dust
extractor. Exceeding the recommended
height and/or weight could result in an
unstable dust extractor would could
cause injury or damage.
NOTICE: Do not remove dust extractor
head from tank with T-stack storage
units attached. Doing so could result in
damage to the dust extractor filters.
SECURING THE POWER CORD TO THE HOSE (FIG. 1)
The power cord (b) can be secured to the suction
hose (g) using the D279058CL hose clip (available
from your local D
WALT supplier).
E
Consult your dealer for further information on the
appropriate accessories.
Troubleshooting
PROBLEM
SOLUTION
Motor
Check power cord, plugs and outlet.
does not
Ensure the on/off switch is in the
run
ON position ( ).
Ensure the tool control switch is in the
OFF position.
PROBLEM
SOLUTION
Suction
Remove blockages in the suction
capacity
nozzle, suction tube, suction hose
decreases
or filters.
Replace the paper or fleece bag.
Check for proper installation of the
filters.
Clean or replace the filters.
Empty canister, refer to Empty
Canister under Operation.
Vacuum
Thermal overload has been tripped:
stops
1. Turn the vacuum off and
running
disconnect vacuum cleaner from
power source.
2. Empty the canister, if needed.
3. Allow the unit to cool.
4. Plug the power cord into an
appropriate outlet and turn on/
off switch to the ON position ( )
to test. If vacuum will not restart
contact your seller or check
the location of your nearest
authorised D
in the D
WALT catalogue or
E
contact your D
address indicated in this manual.
Dust
Check for proper installation of
comes
the filters.
out while
Ensure filters are not damaged;
vacuuming
replace if necessary.
Ensure filter seals are in place and
are secure.
Automatic
Listen for the solenoid clicking to
filter
ensure the filter cleaning mechanism
cleaning
is working.
is not
If vacuum will not restart contact your
working
seller or check the location of your
nearest authorised D
agent in the D
WALT catalogue or
E
contact your D
E
address indicated in this manual.
Power tool
Ensure the tool control switch is in the
does not
ACTIVATION position
turn on.

Protecting the Environment

Separate collection. This product must
not be disposed of with normal
household waste.