Aircare 696 Série Guide D'utilisation Et D'entretien page 9

Masquer les pouces Voir aussi pour 696 Série:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

SUMMER STORAGE
1. Clean unit as outlined in Care & Maintenance section.
2. Discard used wick and any water in the reservoir or bottles and allow to dry
thoroughly before storage. Do not store with water inside reservoir or bottles.
3. Do not store unit in an attic or other high-temperature area, as damage will occur.
4. Install new filter at beginning of season.
TROUBLESHOOTING
Trouble
Digital display not
illuminated.
Not enough humidity
Fan running
continuously.
Poor evaporation of
water.
Neither bottle
emptying.
Bottles continue to
empty after complete
filling.
Left bottle not
emptying.
Bottle empties
completely
Refill display "F" is on
before bottles are
empty.
Probable Cause
• No Power.
• Power button has not
been depressed.
Humidity level is not set
high enough.
• Bottles are empty.
• Wick not absorbing
water
• Float is obstructed.
• Humidity level is set to
highest position
• Humidity level
has not reached the
desired level yet.
• CHECK FILTER (CF)
message flashing.
• Mineral buildup on filter
(wick).
• Unit is not level
• Bottle cap plunger
missing post in bottom of
cabinet
• Dirty wicks.
• Air is entering water
bottle.
• Right bottle contains
water.
• This is normal for initial
filling
• Unit is not set up on a
level surface. (Float
will not sense water at
the front of the
cabinet.)
• Check 120 volt power source.
• Press power button once to
turn on.
• Turn humidity level knob up.
• Increase fan speed.
• Fill humidifier with water.
• Replace wick
• Free float from obstruction
• Setting the humidity to highest
position causes the fan to run
continuously. Adjust the level lower.
• Continue to run until desired
humidity level is achieved. This
may take up to 48 hours initially.
• Change to a fresh new wick
NOTE: Local water varies from area
to area and under certain conditions
minerals will build up more rapidly in
the wick.
• Unplug unit for 1-2 minutes to reset
CF function
• Ensure unit is placed on level area
• Check orientation of bottles.
Reposition so that bottle cap
plunger (stem) is depressed by
post in bottom of cabinet.
• Change to fresh new wick.
• Check valve assembly caps to
ensure tightness.
• Check for leak in water bottle.
• The humidifier is designed so that
right bottle empties first.
• Ensure unit is level .
• Refill bottle for maximum
run time.
• Position unit level. (Some carpet
padding may allow unit to sit lower
in the front than rear with the
additional weight of water bottles in
the front of the cabinet.
9
Remedy
.

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

696800696 400hb

Table des Matières