Crosswind HPPH ON/OFF Model

To install an automation controller that has its own
temperature sensor for HEAT demand to control the
Crosswind HPPH ON/ OFF model.
1. Turn off the electrical power to Heat pump Pool
Heater and pool pump.
2. Remove the Phillips screws that are on the top cover
of the HPPH.
3. To gain access to the electrical components, remove
the four (4) Philips screws on the electrical cover.
See Figure 17.
4. Locate the connection for the AUTOMATION
CONTROLLER terminals. See Figure 18.
5. To install the automation controller cable, cut and
splice the YELLOW jumper wire on Terminal PROT1
to the automation controller cable. See Figure 19.
6. Insert 36" + (1 meter) of cable through the chase to
the PC Control Board. See Figure 20.
7. Program the setpoint to 104
PAD to set the target temperature to 104
to another desired MAX temperature.
NOTE: When the automation controller has a HEAT
demand, the HPPH will be in the HEAT mode.
When the automation controller does not have a HEAT
demand, the HPPH will be in the OFF mode.
Remove the four screws from the electrical cover.
Figure 17. Screw Removal for Electrical Cover
24
(40
) – Press the UP
°F
°C
(40
) or
°F
°C
UNCONTROLLED DOCUMENT IF PRINTED
APPROVED
Figure 18. Automation Controller Cable Connection
Figure 19. Install Automation Controller Cable

Publicité

Chapitres

Table des Matières
loading

Table des Matières