Water Connections

NOTE: Unions Lock-Rings and O-rings are connected
to the Inlet and Outlet of the Heat Exchanger.
A
CAUTION: The heater inlet and outlet connections
are NOT interchangeable. They must be connected as
instructed below.
A
WARNING: Chemical feeders can result in serious
damage to, or premature failure of the heater and may
void the heater warranty. Install a check valve and/
or a Hartford loop AFTER the heater and BEFORE any
chlorinating devices. Install any automatic chemical
feeders AFTER the heater.
1. Connect the heater in the return water line between
the filter and the pool/spa. See the piping layout
shown in Figure 9.
2. Connect the filter outlet to the fitting marked at the
bottom front of the unit.
3. Connect the fitting marked to the return piping to the
pool/spa. The inlet/outlet connection fittings of the
unit are 1-1/2 inch PVC unions.
Water connections from the heater to the main return
line can be PVC pipe or flexible pipe approved for the
purpose and, in either case, should be at least equal in
size to the main pool/spa circulation piping.
CROSSWIND
HEAT PUMP
POOL HEATER
POWER CORD
F10772
APPROVED
WATER TO SWIMMING POOL
OUTLET
SHUT OFF
DIVERTER VALVES
INLET
DRAINAGE
Figure 9.
UNCONTROLLED DOCUMENT IF PRINTED
1. Shutoff diverter valves, preferably three-way valves
which allows for a bypass route, on the inlet and
outlet lines of the heater are required:
a. to protect (completely bypass) the heater from
any harmful chemical treatments (i.e. acid
wash, back-to-back super chlorinators, stain
treatments, etc.); or
b. to isolate the heater for service/repair or freeze
preparation and still allow pool/spa circulation to
continue.
Install any automatic chemical feeders downstream of
the heater. See the piping layout shown in Figure 9.
Note that some municipalities do not allow the use of a
shutoff valve on the effluent/outlet side of any heating
equipment, especially when there is one on the inlet
side. These entities typically instead allow a PVC tee
and spring check valve on the effluent/outlet side. This is
acceptable and can also double as your protection from
chemical feeders and chlorinators that are downstream
of the unit.
Operate the pump and check the system for leaks.
POOL
WATER IN
Piping Layout
FILTER
PUMP
11