Do not plug in or unplug any energized con-
nection plugs into the control unit plug-in.
The device or the opto edges can be de-
stroyed.
The elevator control system can not be ca-
pable of generating or influencing internal
call signals.
No external call signals should be linked to
internal call signals.
The system must be grounded. The "earth"
connection should form a low-resistance
connection ≤ (10 Ω) with the ground. Cor-
rect grounding of opto edges is achieved
automatically during installation.
12
Installation and Operation Manual
4.3.

Recessed mounting kit

A guard plate is mounted on the inside of the cabin.
The opto edges are mounted on the outside of the
cabin (CEDES part no.: 100 847).
4.4.

Surface mounting kit

If there is not enough space on the outside of the
cabin for the opto edges to be mounted there, they
can also be installed on the inside of the cabin using
the surface mounting kit. There is a loss of approxi-
mately 10 cm from the elevator cabin opening
(CEDES part no.: 100 848).