Roland XY Série Mode D'emploi page 39

Table des Matières

Publicité

Instruction
Format
ESC .E
[ESC].E
Output RS-232C
Error Code
ESC .L
[ESC].L
Output I/O buffer
size
ESC .T
[ESC].T<P1>;<P2>;
Set Each Buffer Size <P3> ;<P4>;<P5>;<P6>:
ESC .S
[ESC].Sn:
Output Each Buffer
Size
Abort Instructions
ESC .J
[ESC].J:
Abort Device Cotrol
Instruction
ESC .K
[ESC].K:
Abort RD-GLáU
(RD-GLáV)
Instruction
ESC .R
[ESC].R:
Initialize Device
Control Instruction
Monitor Mode Instructions
ESC .Y
ESC .(
Plotter ON
ESC .Z
ESC .)
Plotter OFF
ESC .@
Set Monitor Mode
and Control DTR
ESC Q
Set Monitor Mode
36
Parameter
Range
None
None
P1: The size of the physical I/O [5120 (byte)]
buffer
P2: The size of the polygon
[3072 (byte)]
buffer
P3: The size of the
[0 (byte)]
downloadable character buffer
P4: Ignored
P5: Ignored
P6: Ignored
n :Buffer type
0-6
[0]
None
None
None
([ ] is default)
Explanation
Outputs an error code related to RS-232C interface
(see the table below), and clears the error simulta-
neously. At the same time, the error being displayed
is canceled.
Error
Meaning
c o d e
0
No I/O errors
10
During an output instruction being executed,
another output instruction is sent (only the
current instruction is effective)
11
An error occurs in a device control instruction.
12
Incorrect parameters are set to a device control
instruction (the default value is set to the erro-
neous parameter)
13
Parameters are overflowing
14
The number of the parameters set is more than
specified or a colon ':' was not used to termi-
nate
15
Framing error, parity error or over-run error at
the time of data receipt
16
The I/O buffer overflows (In this case, the
plotter cannot draw properly.)
17
Baudrate is set incorrectly
18
Other I/O errors occur
Outputs the current logic size of the I/O buffer
Note that the output is done only when the I/O
buffer is empty.
Allocates the 18 KB data buffer to the I/O buffer,
polygon buffer and downloadable character buffer
by defining the parameters.
A [ESC].T instruction without parameters allocates
each buffer size to the default value, and then clears
data in the buffers. If the sum of the four parameters
exceeds 18KB, the allocation of the 18 KB data
buffer is readjusted.
The maximum vale, minimum value and default
value of each buffer are shown in the table below. If
specifying a value more than the maximum, the
maximum value is set. If specifying a value other
than 0 and less than the minimum, the minimum
value is set. If 0 is specified, 2 is set to the I/O
buffer, 4 to the polygon buffer, and 0 to the down-
loadable character buffer.
Buffer type
Min.
value value
I/O buffer
Polygon buffer
Downloadable
character buffer
Outputs the currently set capacity of a User-
definable buffer. The each buffer capacity
corresponding to the parameters 0 to 6 are as
follows.
0: Whole data buffer capacity
1: Physical I/O buffer capacity
2: Polygon buffer capacity
3: Downloadable character capacity
4, 5: Outputs 0 always
Aborts both the currently executed device control
instruction and output.
After executing only the current RD-GLII
instruction, clears the data buffer.
Initializes all settings established by the device
control instructions. However, each buffer size set
by the [ESC].T instruction is taken over.
Ignored.
Ignored.
Ignored.
Ignored.
RD-GL I RD-GL II
Max. Default
value
2 18KB
5120
4 18KB
3072
444 18KB
0

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Dxy-1350aDxy-1150a

Table des Matières